16 Further technical information
16
62
Rittal Liquid Cooling Package
Exterior temperature 10°C
Fig. 65:
Diagrammatic view
Exterior temperature 20°C
Fig. 66:
Diagrammatic view
Exterior temperature 30°C
Fig. 67:
Diagrammatic view
Exterior temperature 42°C
Fig. 68:
Diagrammatic view
Exterior tempera-
ture [°C]
10
Cooling output [kW]
3
6
9
12
Inlet temperature
[°C]
25.62
27.53
29.1
33.18
Outlet temperature
[°C]
22.15
21.56
21.26
23.66
dT [°C]
3.47
5.97
7.84
9.52
Output [kW]
0.825
1.608
2.639
4.02
Tab. 35:
Tabular view
Exterior tempera-
ture [°C]
20
Cooling output [kW]
3
6
9
12
Inlet temperature
[°C]
25.43
27.45
29.07
32.83
Outlet temperature
[°C]
21.86
21.5
21.19
23.2
dT [°C]
3.57
5.95
7.88
9.63
Output [kW]
0.777
1.627
2.717
4.142
Tab. 36:
Tabular view
0
10
20
30
40
0
2
4
6
8
10
12
0
10
20
30
40
0
2
4
6
8
10
12
Exterior tempera-
ture [°C]
30
Cooling output [kW]
3
6
9
12
Inlet temperature
[°C]
25.56
27.59
28.91
33.28
Outlet temperature
[°C]
21.89
21.56
21.16
23.6
dT [°C]
3.67
6.03
7.75
9.68
Output [kW]
0.859
1.772
2.861
4.193
Tab. 37:
Tabular view
Exterior tempera-
ture [°C]
42
Cooling output [kW]
3
6
9
10.46
Inlet temperature
[°C]
25.51
27.32
28.67
30.75
Outlet temperature
[°C]
21.73
21.22
20.46
22.22
dT [°C]
3.78
6.1
8.21
8.53
Output [kW]
1.084
2.258
4.182
4.521
Tab. 38:
Tabular view
0
10
20
30
40
0
2
4
6
8
10
12
0
10
20
30
40
0
2
4
6
8
10
12