DIAL CODE
DESCRIPTION
PHRASE REPEATS IN EACH MESSAGE:
(continued)
SWITCH 1 CLOSED
7-1-2-1
One time DEFAULT
7-1-2-2
Two times
7-1-2-3
Three times
7-1-2-4
Four times
7-1-2-5
Five times
7-1-2-6
Six times
7-1-2-7
Seven times
7-1-2-8
Eight times
7-1-2-9
Nine times
SWITCH 2 OPEN
7-2.1-1
One time DEFAULT
7-2-1-2
Two times
7-2-1-3
Three times
7-2-1-4
Four times
7-2-1-5
Five times
7-2-1-6
Six times
7-2-1-7
Seven times
7-2-1-8
Eight times
7-2-1-9
Nine times
SWITCH 2 CLOSED
7-2-2-1
One time DEFAULT
7-2-2-2
Two times
7-2-2-3
Three times
7-2-2-4
Four times
7-2-2-5
Five times
7-2-2-6
Six times
7-2-2-7
Seven times
7-2-2-8
Eight times
7-2-2-9
Nine times
DEBOUNCE OPTIONS
SWITCH 1 MODENORMAL
8-1-1
Normal On/ Off
SWITCH 1 MODEDEBOUNCED CONTACT
8-1-2-1
No contact debounce
8-1-2-2
10 seconds of debounce
8-1-2-3
30 seconds of debounce
8-1-2-4
1 minute of debounce
8-1-2-5
3 minutes of debounce
8-1-2-6
5 minutes of debounce
SWITCH 1 MODEHOLDOFF CONTACT
8-1-3-1
No contact holdoff
8-1-3-2
10 seconds of holdoff
8-1-3-3
30 seconds of holdoff
8-1-3-4
1 minute of holdoff
8-1-3-5
3 minutes of holdoff
8-1-3-6
5 minutes of holdoff
SWITCH 2 MODENORMAL
8-2-1
Normal On/ Off
SWITCH 2 MODEDEBOUNCED CONTACT
8-2-2-1
No contact debounce
8-2-2-2
10 seconds of debounce
8-2-2-3
30 seconds of debounce
8-2-2-4
1 minute of debounce
8-2-2-5
3 minutes of debounce
8-2-2-6
5 minutes of debounce
SWITCH 2 MODEHOLDOFF CONTACT
8-2-3-1
No contact holdoff
8-2-3-2
10 seconds of holdoff
8-2-3-3
30 seconds of holdoff
8-2-3-4
1 minute of holdoff
8-2-3-5
3 minutes of holdoff
8-2-3-6
5 minutes of holdoff
DIAL CODE
DESCRIPTION
LATCHING OPTIONS
/
SWITCH 1 MODEON/ OFF
8-1-4
Latch off DEFAULT
8-1-5
Latch on
SWITCH 1 MODEINPUT TYPE
8-1-6-1
Contact closure DEFAULT
8-1-6-2
Analog Input
8-1-6-3
Terminated Alarm Input
SWITCH 1 MODELOW THRESHOLD SETPOINT
8-1-7-x-x-x 0-0-0
=
0 volt
0-5-1
=
1 volt
0-8-4
=
1.68 volts DEFAULT
1-0-2
=
2 volts
1-5-3
=
3 volts
2-0-4
=
4 volts
2-5-5
=
5 volts
SWITCH 1 MODEHIGH THRESHOLD SETPOINT
8-1-8-x-x-x 0-0-0
=
0 volt
0-5-1
=
1 volt
1-0-2
=
2 volts
1-5-3
=
3 volts
1-7-1
=
3.42 volts DEFAULT
2-0-4
=
4 volts
2-5-5
=
5 volts
/
SPECIAL FEATURES:
CONFIGURATION
9-1-1
Configure to One Contact Input DEFAULT
9-1-2
Configure to Two Contact Inputs
ALERT BEEPS
9-2-1
One beep DEFAULT
9-2-2
Two beeps
9-2-3
Three beeps
9-2-4
No beeps
BATTERY SAVER
9-3-1
Off
9-3-2
On DEFAULT
LOW BATTERY MESSAGE
9-4-1
Off
9-4-2
On DEFAULT
9-4-3
Alkaline batteries DEFAULT
9-4-4
Ni-Cd batteries . . . . . . . . . . . . .
EXTERNAL POWER MESSAGE
9-5-1
Off DEFAULT
9-5-2
On
TRANSMIT DELAY IN 1/32 SECOND INCREMENTS
9-6-x-x-x
0-0-0
=
No Delay
0-2-4
=
3/4 second DEFAULT
0-3-2
=
1 second
0-6-4
=
2 seconds
0-9-6
=
3 seconds
1-2-8
=
4 seconds
1-6-0
=
5 seconds
1-9-2
=
6 seconds
2-2-4
=
7 seconds
2-5-5
=
7-
31
/
32
seconds
RESTORE FACTORY DEFAULTS
9-7-8
VHF (Frequency = 154.570 MHz)
9-7-9
UHF (Frequency = 467.925 MHz)
END TELEPHONE PROGRAMMING
9-9-9
End telephone programming & RESTART
{
NOTE:
For
Switch 1
ONLY
{
IMPORTANT:
See J103
settings,
page 15.
Q
UICK
T
ALK
A
DVANCED
F
EATURES