background image

RADIO PROGRAMMING

 

 

Have questions?  Call 

800-USA-1-USA

 (800-872-1872) or visit our website at 

www.ritron.com

 

page 

15

 

 
TABLE 2:  INTERFERENCE ELIMINATOR 
PROGRAMMABLE QC TONE 

Code 

Hz 

Code 

Hz 

Code 

Hz 

01 

67.0 

18 

123.0 

35 

225.7 

02 

71.9 

19 

127.3 

36 

233.6 

03 

74.4 

20 

131.8 

37 

241.8 

04 

77.0 

21 

136.5 

38 

250.3 

05 

79.7 

22 

141.3 

39 

  69.4 

06 

82.5 

23 

146.2 

40 

159.8 

07 

85.4 

24 

151.4 

41 

165.5 

08 

88.5 

25 

156.7 

42 

171.3 

09 

91.5 

26 

162.2 

43 

177.3 

10 

94.8 

27 

167.9 

  44    No Tone 

11 

97.4 

28 

173.8 

45 

183.5 

12 

100.0 

29 

179.9 

46 

189.9 

13 

103.5 

30 

186.2 

47 

196.6 

14 

107.2 

31 

192.8 

48 

199.5 

15 

110.9 

32 

203.5 

49 

206.5 

16 

114.8 

33 

210.7 

50 

229.1 

17 

118.8 

34 

218.1 

51 

254.1 

 

 

 

 

00 

 Delete 

 

TABLE 3:  DIGITAL INTERFERENCE ELIMINATOR 
PROGRAMMABLE DQC TONE

 

CODE NUMBERS 

023 

072 

152 

244 

311 

412 

466 

632 

025 

073 

155 

245 

315 

413 

503 

645 

026 

074 

156 

246 

325 

423 

506 

654 

031 

114 

162 

251 

331 

431 

516 

662 

032 

115 

165 

252 

332 

432 

523 

664 

036 

116 

172 

255 

343 

445 

532 

703 

043 

122 

174 

261 

346 

446 

546 

712 

047 

125 

205 

263 

351 

452 

565 

723 

051 

131 

212 

265 

356 

454 

606 

731 

053 

132 

223 

266 

364 

455 

612 

732 

054 

134 

225 

271 

365 

462 

624 

734 

065 

143 

226 

274 

371 

464 

627 

743 

071 

145 

243 

306 

411 

465 

631 

754 

 

HOW TO FIELD PROGRAM RADIO FEATURE CODES  

1.   Follow the instructions in FIG-7 on page 12 to place the base station in the Program / 

Readout Mode.  

2.   Using the PTT (push-to-talk) button and the LED display, enter the single digit code 

from Table 4 below for the option to be programmed.  

3.   Pause

—the display will change and show a hyphen, you will also hear a short low 

tone.  

4.   Press and release the On / Volume Up to SAVE your programming entry. The base 

station will sound a triple beep to indicate that programming was successful.  

5.   Turn the base station OFF and then ON again

—the base station is now ready to use.  

 

TABLE 4:  Radio Feature Codes 

Option

 

 

Code

 

Turn Channel Scan 

ON

 

Turn Channel Scan 

OFF

 

Turn Weather Channel 

ON

 

Turn Weather Channel 

OFF

 

Turn Weather Alert  

ON

 

Turn Weather Alert  

OFF

 

Assign 

SCAN

 option to 

Z Button

 

Assign 

WEATHER

 option to

 Z Button

 

Assign 

MONITOR

 option to 

Z Button

 

Assign 

CALL TONE

 option to 

Z Button

 

 

NOTES:  

 

1. 

If Code 7 is selected Codes 1 & 2 will have no effect 

 

2. 

If Code 8 is selected, Codes 3 & 4 will have no effect  

3. 

Code 0 is entered by pressing the PTT 10 times

Summary of Contents for DISPLAY Series

Page 1: ...MODELS JBS 146i TYPE OF UNIT VHF FM 2 Way Desk Top Radio FCC ID AIERIT37 146I DATE April 29 2014 Included in this exhibit is a draft copy of the User Manual for RITRON Model JBS 146i VHF FM 2 Way Des...

Page 2: ...9 VHF Table Frequencies for Easy Field Programming Built in Quiet Call and Digital Quiet Call Interference Eliminator Up to 10 Channel Capability 12 VDC or Wall Outlet 120 VAC Operation NOAA Weather C...

Page 3: ...tenna RAM I545 Magnet mounted Dual band Antenna w BNC RPS IB Replacement 110 VAC Power Supply CCL M 12 VDC Cigarette Lighter Adaptor JBSK I2 12 VDC Adaptor Kit REP 2 Low Profile Earphone RHD IX Single...

Page 4: ...Table 1 Programmable Frequency Codes 14 Table 2 Programmable QC Tone Codes 15 Table 3 Programmable DQC Codes 15 How to Field Program Radio Feature Codes 15 Table 4 Radio Feature Codes 15 How to Delete...

Page 5: ...Ritron JBS PBS Display Series base stations A rugged programmable two way desktop base station designed to operate in a professional FM communications band VHF or UHF business available Each radio is...

Page 6: ...2013 FCC NARROWBAND MANDATE On January 1 2013 pursuant to the FCC Narrowband mandate Ritron will no longer be allowed to manufacture wide band 25 kHz capable radio equipment that operates in the freq...

Page 7: ...either an external 12 VDC supply or the RPS 1B cube power supply included with the radio 7 ANTENNA The flexible antenna radiates and receives radio signals The antenna connects to a BNC type connector...

Page 8: ...selected and you press the Channel Selector button the radio resets to channel 1 and the Channel Beep is heard on the speaker If the Scan Channel is selected the radio will sound the Scan Beep and the...

Page 9: ...arrier Squelch and you can Monitor all broadcasts on the channel To exit Carrier Squelch press and hold both volume buttons until you hear the SINGLE beep 3 If the base station emits a TRIPLE beep the...

Page 10: ...e a SINGLE beep will sound to indicate that tone squelch is on A DOUBLE beep means that carrier squelch is on If the channel is programmed for 2 Tone Code a TRIPLE beep indicates that the base station...

Page 11: ...the Channel Selector button The first channel in the scan list cannot be blocked To turn Channel Scan On Off see How to Field Program Radio Feature Codes on page 15 Last Channel Scanned Alert Tone Whe...

Page 12: ...eleasing The radio sounds three beeps when 2 Tone Decode is turned on If you are unable to set the base station you have selected a channel that is not programmed for 2 Tone Decode When the base stati...

Page 13: ...or 2 Tone Paging Functions on page 5 CALL TONE When the Z button is pressed the radio transmits a Call Tone on the channel currently selected If you continue to hold the Z button down the transmitter...

Page 14: ...e network of radio stations broadcasting continuous weather information direct from a nearby National Weather Service office NWR broadcasts National Weather Service warnings watches forecasts and othe...

Page 15: ...on VHF band base stations To select NOAA Weather press the Z button The base station will scan to the 1st NOAA frequency where a broadcast is present The display will light a single segment to indica...

Page 16: ...mber will appear briefly on the display as you step through the channels When you have settled on a channel a hyphen will appear across the center of the display to indicate that it is ready for reado...

Page 17: ...radio will sound a low tone and show a hyphen across the center of the display to indicate that it is ready to accept the next digit 8 Enter the 2nd digit of the frequency code by clicking the PTT but...

Page 18: ...463 2625 12 5 18 464 9125 12 5 19 464 6000 12 5 20 464 7000 12 5 21 462 7250 12 5 22 464 5000 Brown Dot 12 5 23 464 5500 Yellow Dot 12 5 24 467 7625 J 12 5 25 467 8125 K 12 5 26 467 8500 Silver Star...

Page 19: ...32 223 266 364 455 612 732 054 134 225 271 365 462 624 734 065 143 226 274 371 464 627 743 071 145 243 306 411 465 631 754 HOW TO FIELD PROGRAM RADIO FEATURE CODES 1 Follow the instructions in FIG 7 o...

Page 20: ...the receiver that does not carry the correct code This feature is usually used in conjunction with Monitor Lock Out Transmit Time Out time can be changed Power Saver sleep time can be set or power sa...

Page 21: ...those mentioned below have not been tested for compliance and may or may not meet the exposure limits at the distances given Higher gain antennas are capable of generating higher fields in the strong...

Page 22: ...pages 3 through 9 If you think the base radio is malfunctioning check the list below Problem Possible Solutions GENERAL The radio does not work at all Make sure the 120 VAC outlet is active and the R...

Page 23: ...you want to program a 2 Tone Code into 4 Enter the 1st digit of the 2 Tone code by clicking the PTT button until the program display shows the desired number Pause the radio will sound a low tone and...

Page 24: ...s all operators of these frequencies to obtain a station license before operating their equipment Make application for your FCC license on FCC Forms 600 and 159 To have forms and instructions faxed to...

Page 25: ...ITRON Warranties implied by state law such as implied warranties of merchantability and fitness for a particular purpose are limited to the duration of this limited warranty as it applies to the cover...

Page 26: ...y pressing the Volume Down Off button The only way to turn the radio off is to remove power Will restart to a mid volume level after a power outage As an alternative this option can be disabled using...

Reviews: