4
5.
Unit designation
Unit
Designation
1
Panic button.
2
Button for changing operating modes.
3
Connector for 868 MHz antenna installation.
4
Special cable connector for communication with PC USB1 or USB2
.
Used for updating version of the button software.
5, 6
Connectors for battery installing:
•
Connector
6:
for positive battery terminal connection;
•
Connector
5:
for negative battery terminal connection.
7
Terminals for connecting an additional panic button.
6.
Visual indication
Indicator
State
Value
Rx+Tx
Blink one time
The button is added to the radio system of
the radio channel receiver.
Flash for 5 seconds
The radio system is not found
Rx
Blinks one time
The transmitted alarm is received by the
radio channel receiver.
Tx
Blinks up to 5 times
at 1
time per 2 seconds
Failed to transmit the alarm.
Blinks two times
every 6 seconds
Battery is discharged.
2
The panic button tries to transmit an alarm five successive times.
+
_
Tx
Rx
1
2
3
4
5
6
7