ritm Contact GSM-14 Wi-Fi Datasheet Download Page 5

 

5

 Element 

Designation 

1 Fixing 

holes 

4 holes for fixing to surface 

+12V, GND, SIREN 

Terminals for connecting power supply and 
wired siren: 

 

+12V – power supply “plus” (if using 
external power supply 12V); 

 

GND – power supply “minus” (if using 
external power supply 12V) and “minus” of  
the siren; 

 

SIREN – «plus» of  the siren. 

3 SA1 

Tamper button 

Connector for power adapter 

Connect the power adapter (included in scope of 
delivery) 

JMP 1, 2, 3 

Connectors for jumpers 

6 SIM1 

Main SIM-card 

7 SIM2 

Redundant SIM-card 

Location for the battery 

Connector for battery BL-5C  connection  
 (included in scope of delivery) 

9 Buzzer 

Audible signals (see paragraph 6) 

10 Button 

When clicking an alarm event is generated  
(see section 7) 

11 Indicators 

Light indication of the panel basic parameters 
(see section 6) 

6.

 

Indication

 

The device has 4 visual (blue) indicators at its front panel. 
To turn on the visual indication and the audio signal (buzzer), configure their operating 

modes in the configuration software. The following visual indication settings are available: 

 

Device power supply status; 

 

Availability of unsubmitted events; 

 

Device registration in GSM network; 

 

Status of sensors in one area. 

Audio indication: 

 

Successful registration in GSM network; 

 

Incoming call; 

 

Input delay; 

 

Output delay; 

 

Alarm in area; 

7.

 

Panic button 

 

Panic button. Creates an event that is recorded into the device history 
and transmitted over configured data links. The event code is specified 
in the configuration software. Inactive by default. 

 