4 Before you Connect Wires

Caution

Do not allow wires to touch each other or par ts on thermostat. 
Wires must be routed through the hole in the back plate , below the 
terminal block, or they will hit par ts on the cover. 

Please follow these guidelines for safe and secure wire connections.

Determine which step-by-step wiring diagram you should use. Make sure your 
wires are labeled. This may require you to find the 'other end' connection for each 
wire on your heating or air conditioning equipment and read the label there.
     If you have a wire marked "C" its connection is optional. If you do connect it the 
thermostat will draw power from the C wire and this will extend battery life. 

Optional Wire Connections 

 What Wires Do you Have?

Strip insulation 3/8 in. (9.5mm) from wire ends. 
Take care not to damage the labels for each wire in handling.
Connect labeled wires only to a terminal with corresponding letter.
Bend the wire slightly, insert the wire under the contact plate and 
tighten the screw down onto the wire.  

PG

 6

PG

 5

RH
G

Y

W

C

From Furnac

e

And AC unit

R

or

B

G

Y

R

C

From single 

stage 

heat pump

O

or

RC
G

Y

W

C

From Furnac

e

And AC unit

RH

Go To Page 13

Go To Page 14

Go To Page 12

RH

W

C

From Furnac

e

G

W

RH

R

or

From Furnac

e

Go To Page 11

C

Go To Page 15

R  -  Single source power for heat/cool
       Note: R connects to both RC and RH using the red jumper
RH or R - HEATING POWER

RC - COOLING POWER
W -  HEATING CONTROL
G -  FAN RELAY  

C -  Common side of Heating Power
Y -  COMPRESSOR
O - DAMPER OR CHANGEOVER VALVE (POWERED IN COOL)

B -  DAMPER OR CHANGEOVER VALVE (POWERED IN HEAT)  

or R

Summary of Contents for 8029B

Page 1: ...307 007 Install guide 8029B Customer Support 888 515 2585 or Visit our website www ritetemp thermostats com HEAT COOL AUTO ON OFF FAN HEAT COOL AUTO ON OFF FAN ROOM TEMP ROOM TEMP...

Page 2: ...mage to the thermostat On replacement installations mount the new thermostat in place of the old one if possible On new installations follow the guidelines listed below Locate the thermostat on an ins...

Page 3: ...back of unit Press up on the catch on bottom of thermostat and swing the body away from the base lift up to remove the body from the base Hold the base against the wall with the wires coming through t...

Page 4: ...tional Wire Connections What Wires Do you Have Strip insulation 3 8 in 9 5mm from wire ends Take care not to damage the labels for each wire in handling Connect labeled wires only to a terminal with c...

Page 5: ...batteries you have 30 seconds before your custom program is lost Follow these procedures to verify you have correctly installed the unit To check HEAT mode Set the mode switch to HEAT Set the fan swi...

Page 6: ...er Options 6 Check Unit cont Congratulations you have successfully installed your unit Please proceed to the OPERATING Guide to initialize the new thermostat PG 9 PG 10 Inside of Unit GAS ELECT AA AA...

Page 7: ...onnect the W wire to the W terminal on the thermostat This connects the heater control line to the thermostat STEP 3 Connect the G wire to the G terminal on the thermostat This connects the Fan to the...

Page 8: ...on the thermostat This connects to the Cooler compressor STEP 3 Connect the RH wire to the RH terminal on the thermostat This connects to the Heater Power STEP 4 Connect the RC wire to the RC terminal...

Page 9: ...AC unit R G Y C O or B O or B Single Stage HEAT PUMP Change Over G O or B R C FAN Y Comp 24VAC Power jumper wire jumper wire Thermostat The 8029B can be used with most 24 volt gas oil or electric hea...

Reviews: