2 Remove old unit

IMPORTANT : LABEL ALL WIRES 
BEFORE DISCONNECTING THEM!

3 Mount the 8029B

Switch electricity to the furnace and 
air conditioner OFF; 
then proceed with the following steps.
Remove cover from old thermostat. Most are snap-on types 
and simply pull off. Some have locking screws on the side 
or front. These must be loosened.   Note the letters printed 
near the terminals. Attach labels (enclosed) to each wire for 
identification.

Label the wires one at a time.  

You must have all the wires labeled 

before you proceed.

 With all wires labeled, remove them from the old unit.

Make sure the wires 

do not fall back inside

 the wall.  Wind them around a 

pencil to 

keep them from falling

.

Loosen all screws on the old thermostat and remove it from the wall.
Fill wall opening with non-combustible insulation to prevent drafts.  

Separate front from back of unit. Press up on the 
catch on bottom of thermostat and swing the body 
away from the base, lift up to remove the body from 
the base. 
Hold the base against the wall, with the wires 
coming through the opening below the terminal block. 
Position the base for best appearance. Use 
the optional wall plate to cover blemishes 
on wall from your old thermostat.
Attach the base to the wall with the two 
screws provided.
If you are mounting the base to sheet rock 
or if you are using the old mounting holes, 
use the plastic anchors provided. Drill a 
3/16-in.(4.8mm) hole for the insert at each 
screw location, then mount the base.

PG

 3

PG

 4

B

G

W

Caution

C  RC O B R

H W Y G  

HEA

T    

      

 COO

L

AUT

O    

    O

N

OFF

FAN

Read instructions carefully before removing any wiring from existing thermostat. 
Wires must be labeled before they are removed. 

THERE IS NO STANDARD 

COLOR CODE.

 When removing wires from their terminals, ignore the color of the 

wires since these may not comply with the standard.

C  RC O B R

H W Y G  

Terminal 
Block

Wall Plate

Thermostat Base

ROOM

 TEMP

Summary of Contents for 8029B

Page 1: ...307 007 Install guide 8029B Customer Support 888 515 2585 or Visit our website www ritetemp thermostats com HEAT COOL AUTO ON OFF FAN HEAT COOL AUTO ON OFF FAN ROOM TEMP ROOM TEMP...

Page 2: ...mage to the thermostat On replacement installations mount the new thermostat in place of the old one if possible On new installations follow the guidelines listed below Locate the thermostat on an ins...

Page 3: ...back of unit Press up on the catch on bottom of thermostat and swing the body away from the base lift up to remove the body from the base Hold the base against the wall with the wires coming through t...

Page 4: ...tional Wire Connections What Wires Do you Have Strip insulation 3 8 in 9 5mm from wire ends Take care not to damage the labels for each wire in handling Connect labeled wires only to a terminal with c...

Page 5: ...batteries you have 30 seconds before your custom program is lost Follow these procedures to verify you have correctly installed the unit To check HEAT mode Set the mode switch to HEAT Set the fan swi...

Page 6: ...er Options 6 Check Unit cont Congratulations you have successfully installed your unit Please proceed to the OPERATING Guide to initialize the new thermostat PG 9 PG 10 Inside of Unit GAS ELECT AA AA...

Page 7: ...onnect the W wire to the W terminal on the thermostat This connects the heater control line to the thermostat STEP 3 Connect the G wire to the G terminal on the thermostat This connects the Fan to the...

Page 8: ...on the thermostat This connects to the Cooler compressor STEP 3 Connect the RH wire to the RH terminal on the thermostat This connects to the Heater Power STEP 4 Connect the RC wire to the RC terminal...

Page 9: ...AC unit R G Y C O or B O or B Single Stage HEAT PUMP Change Over G O or B R C FAN Y Comp 24VAC Power jumper wire jumper wire Thermostat The 8029B can be used with most 24 volt gas oil or electric hea...

Reviews: