TROUBLESHOOTING
LED Status Chart – Standalone Controls
? = Varies (depending on operation)
F = Off
ITL = Interlock input on
M = Lights when button pressed
P = Pulsing / Flashing
(set to steady using DIP switches)
T = Steady On
LEVELER CONTROL BOARD
INPUTS
OUTPUTS
FIELD
PUSH
BUTTONS
12VDC
AR
TD INPUT
COMBINED POWER UNIT
INPUT
[CMBD PU]
GREEN LIGHT
T
O OPERA
TE
LEVELER INPUT
[GL
T ITL]
[SEE DIP
SWITCH #2]
OVERHEAD DOOR OPEN INTERLOCK INPUT
[OHD ITL]
[SEE DIP
SWITCH #3]
RAISE PUSH BUTT
ON
MOT
OR CONT
ACT
OR OUTPUT
[L
VLR CONTR]
12VDC POWER SUPPL
Y OK
TERMINAL BLOCK NO.
J92
J112
J111
J91
J164
J103
J101–2
LEVELER CONTROL BOARD LEDS
LD5
LD3
LD2
LD4
LD14
LD6
LD1
LEVELER AUX BOARD LEDS
–
–
–
–
–
–
–
N
O
.
020100
State/Sequence
No
Rest State
F
F
?
?
–
F
T
020101
Raise Sequence
F
F
ITL
ITL
M
T
T
020102
Automatic Return to Dock
T
F
ITL
ITL
–
T
T
020103
Combined Power Unit Seq
F
T
?
?
–
T
T
020500
Run Fault State
?
?
?
?
?
F
T
RUN FAULT STATE
If Leveler Motor is operated continuously for 60 seconds, system will enter RUN FAULT STATE
After a 60 second rest period, system will automatically enter the REST STATE and resume normal operation
LED Status Chart – Dok-Commander Controls
? = Varies (depending on operation)
F = Off
ITL = Interlock input on
M = Lights when button pressed
P = Pulsing / Flashing
(set to steady using DIP switches)
T = Steady On
MICRO CONTROL BOARD
POWER
BOARD
INPUTS
OUTPUTS
FIELD
PUSH
BUTTONS
12VDC
12VDC
AR
TD INPUT
OVERHEAD DOOR OPEN INTERLOCK INPUT
[OHD ITL]
LEVELER ST
ORED
INTERLOCK T
O
UNLOCK
[UNLK ITL]
RAISE PUSH BUTT
ON
MOT
OR CONT
ACT
OR
OUTPUT
[L
VLR CONTR]
12VDC POWER SUPPL
Y OK
TERMINAL BLOCK NO.
J144
J142
J143
Membrane
J151
J21‑6
MICRO CONTROL BOARD LEDS
LD32
LD29
LD30
LD52
LD42
LD7
LEVELER AUX BOARD LEDS
–
–
–
–
–
–
N
O
.
020100
State/Sequence
No
Rest State
F
?
?
–
F
T
020101
Raise Sequence
F
ITL
?
M
T
T
020102
Automatic Return to Dock
T
ITL
?
–
T
T
020103
Combined Power Unit Seq
F
?
?
–
T
T
020500
Run Fault State
?
?
?
?
F
T
RUN FAULT STATE
If Leveler Motor is operated continuously for 60 seconds, system will enter RUN FAULT STATE
After a 60 second rest period, system will automatically enter the REST STATE and resume normal operation
RHA-4000 Dock Leveler
Owner's Manual