i-COMM™ CONTROLLER

4

Pub. No. RHSPI388 JANUARY 2006

i-COMM DIGITAL CONTROLLER INSTRUCTIONS

LCD DISPLAY MESSAGES:

TOP DISPLAY

BOTTOM DISPLAY

REASON

ACTION REQUIRED

FAULT MESSAGES

Door Faulted

Normal Power Up 

Indicates Loss of Power

Push Open/Reset*

Watchdog Timer 

Indicates the boards watchdog timer has reset

Service Required*

Reset From Sleep

Indicates the controller was awaken from sleep mode Service Required*

Low Voltage

Drop in voltage caused controller to restart

Push Open/Reset*

Breakaway

Door is in breakaway mode

Reset / Jog Door*

Breakaway

Sideframe door (8000CL/XL), Overload Relay (8000/CL/XL) Reset / Jog Door*

Emergency Stop

E-Stop pushed, Overload Relay (8900), Inverter (8600) Push Open/Reset*

Open Time Limit

Run open time limit exceeded

Service Required*

Menu Interrupt

Menu Interrupted

Push Open/Reset*

Limit Pulse Fail

Trakline limit problem (8910/20/PL only)

Service Required*

Limit Failure

Limit switch has failed

Service Required*

Obstruction

Door has detected obstruction and reversed 3 times

Inspect & Reset*

Unknown

Unknown fault

Service Required*

System Clock read

System clock failed

Service Required*

Unknown State

State unknown 

Service Required*

Pro System

Pro Inverter Fault

Check Inverter*

Jog to Open Pos

Displays when jogging open

None*

Jog to Close Pos

Displays when jogging close

None*

* Displays on Screen

DOOR IS OPENING

Door is Opening

DOOR IS OPEN

Door is Open

When not in preannounce to close

None

Stand Clear 

When in preannounce to close

None

Closing in xx.xs

Displays closing time in seconds

None

Activation On

Indicates activation on (overrides timer display)

Device Holding Open

Waiting for cmd.

Indicates door is waiting for manual close cmd.

Close Door

Photoeye Blocked

Photoeye is blocked (overrides timer display)

Remove Obstruction

I-Zone Detection

I-Zone active (overrides timer display)

Remove Detection

DOOR IS CLOSING

Stand Clear

Door Closing

None

DOOR IS CLOSED

Door Closed

Cycles: xxxxxx

Displays cycle count

None

Door Closed

Interlock Active

Door is interlocked and cannot be opened

Perform Interlocking

DOOR IS STOPPED

Door Stopped

Push Open/Close

Open/Close Door

Summary of Contents for i-COMM

Page 1: ...i COMM CONTROLLER Pub No RHSPI388 JANUARY 2006 1 i COMM DIGITAL CONTROLLER INSTRUCTIONS...

Page 2: ...5 Unplug the J5 induction loop harness if applicable 6 Remove wires from the input and output terminals 7 Remove the board by cutting the white plastic supports and remove supports from bracket 8 Ins...

Page 3: ...ROLLER INSTRUCTIONS Input Terminals LCD Display Output Terminals Display Contrast Potentiometer Lighter Darker Down Key Up Key Enter Key J1 Programming Port Green Input Terminal LED s Power LED Red Ou...

Page 4: ...Door has detected obstruction and reversed 3 times Inspect Reset Unknown Unknown fault Service Required System Clock read System clock failed Service Required Unknown State State unknown Service Requi...

Page 5: ...4VAC INPUT 24VAC COMMON N OPEN CLOSE COM INVERTER OUT 2 K1 INVERTER OUT 1 K0 LOOP INPUT 2 LOOP INPUT 1 DC POWER OUT DC COMMON OUT DC POWER OUT LOOP INPUT X13 BARRIER GLIDER 7100 OPEN L S CLOSE L S SPA...

Page 6: ...Read Write Displays and sets Preannounce to close timer This time plus the Close Timer will be the amount of time the door will stay open Valid Range 0 255 seconds All models Display Serial Read Only...

Page 7: ...for 60 seconds 15 On when door open for 120 seconds 16 On during sequential activation 17 On when not running open 18 On when not running close 19 On when not running open or close 20 Output Disabled...

Page 8: ...ult History Read Only Displays Last five faults as codes Use arrows to provide a detailed description of each fault code displayed Kick Close Time Read Write Sets Kick Time on Barrier Fold door Valid...

Reviews: