background image

disconnec

ti

ng your ManTooth PT Module from 

the system.  

ManTooth Thermistor Clamp

 

The thermistor pipe clamp probe is capable of 
clamping to and measuring the temperature of 
pipes ranging in size from ¼ inch to 1 

 inches. 

The probe is capable of measuring with an 
accuracy of 0.2°C from 0°C to 70°C with a full 
range of -40°C to 130°C. For best long term 
stability of your thermistor pipe clamp probe 
avoid storing it at temperatures exceeding 75°C 
(167°F). 

Thermistor Probe Jacks 

Each ManTooth PT Module is equipped with 2 
temperature probe jacks for use with 
ManTooth Thermistor Clamps.  

Instrumenta

ti

on Speci

ca

tion

 

Pressure 
Sensing 
Resolu

ti

on 

0.1 psi, 0.1 bar, 1 kPa, 0.01 
MPa, 0.01 kg/cm^2  

Pressure 
sensing 
accuracy 

0.5% of full scale at 25°C 
1% of full scale 55°F to 130°F 
2% of full scale -40°F to 248°F 

Working 
Pressure 

0 to 700 psia (48.3 bar) 

Proof 
Pressure 

Tolerable pressure without 
internal damage 
1000 psia 

Burst Pressure  Tolerable pressure without 

loss of seal 
1500 psia 

Temperature 
Sensor Range 
(instrument) 

Sensing element 
-40°F to 266°F 
(-40°C to 130°C) 
Max Cord temp  
176°F  (80°C) 
Max Clamp Temp 
203°F (95°C) 

Temperature 
Display 
Resolu

ti

on 

0.1

°F or °C 

Temperature 
Accuracy 
(Instrument) 

±0.2°C (±0.36°F) 

Working 
Temperature 

-4°F to 160°F Limited by 
ba

tt

ery 

Storage 
Temperature 

-4°F to 160°F 
For best ba

tt

ery performance 

do not store at over 100°F 

Working 
humidity 

0 to 95% RH (non-condensing) 

IP Class 

IP 50 

Ba

tt

ery Life 

10+ hours con

ti

nuous 

Range 

Up to 400 Feet 
Limited by Phone or Tablet 
Bluetooth radio strength 

Bluetooth 
Radio 

Class 1 Bluetooth 2.1 Radio 

Size 

6” long x 1.6” wide x 2.3” thick 
(15.3 x 4 x 5.8 cm) 

Weight 

0.5 lbs (225 grams) 

Superheat 
and Subcool 

Automa

ti

cally calculated by 

the ManTooth App 

Max. and Min. 
Pressures 

Displays and records the 
maximum and minimum 
pressures 

Refrigerant 
Database 

98 NIST refrigerant pro

les 

included; upgradeable 

Share 
Screenshots 

Screenshot feature allows you 
to save pressure and 
temperature readings from 
your sessions which can be 
automa

ti

cally organized by 

loca

tion 

and unit being 

serviced 

Temperature 
Sensors 

Capable of measuring 2 
temperatures using high 
accuracy NTC thermistors 

Pressure 
Transducers 

67001 – one pressure 
transducer 
67002 – two pressure 

14

Summary of Contents for Yellow Jacket ManTooth Series

Page 1: ...rks of Google Inc The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of such marks by Ritchie Engineering is under license Other trademarks and trade names are those of their respective owners Made for iPhone and Made for iPad mean that an electronic accessory has been designed to connect specifically to iPhone or iPad respectively and has been certi...

Page 2: ...rovided by the equipment may be impaired Do not use the instrument if it is damaged Before you use the instrument inspect the case Look for cracks or loose components The instrument contains no internal user serviceable parts Do not open the instrument Have the instrument serviced only by Ritchie Engineering Co or authorized service centers Do not use the instrument if it operates abnormally Prote...

Page 3: ...rgers to recharge the ManTooth PT Module as this could damage the circuitry and or battery Only use with refrigerants approved for use with the ManTooth PT Module Use of unapproved refrigerants may cause damage to the ManTooth PT Module A complete list of approved refrigerants can be found in the ManTooth RSA app in the Select Refrigerant option Getting Started The ManTooth PT Module is a precise ...

Page 4: ...eleasing the power button on the main module If you have a 67002 dual unit the main module is the one that says ManTooth PT Module on the label not the one that says ManTooth PT Tether Module The module will go through a brief start up sequence then the light on your ManTooth PT Module should start to blink blue This means that your ManTooth PT Module is searching for available Bluetooth devices t...

Page 5: ...various functions settings and procedures of the ManTooth RSA Pressure Temperature App If you have not already downloaded the Yellow Jacket ManTooth RSA Pressure Temperature App go to either the Apple App Store or the Google Play Store now to download the free app You can either use the QR code links that are on your ManTooth PT Module packaging follow the links that are available on YellowJacket ...

Page 6: ...hat the temperature readings from the temperature sensors Vapor Saturation Liquid Saturation and the values for Superheating and Subcooling are displayed in Options are degrees Fahrenheit F or degrees Celsius C Default temperature units are degrees Fahrenheit F Pressure Preference Set the units that the pressure readings are displayed in Available units are bar pounds per square inch absolute psia...

Page 7: ... off timer if you wish to reset the timer simply tap anywhere on the screen Also included is an auto off never setting Moving the slider all the way to the left will set the auto off timer to never Default is Auto Off 5 min Getting Back to the Previous Screen To return to the previous screen from the one you are currently viewing tap on the icon in the upper left hand corner This function is the same...

Page 8: ...r the current session tap on Refrigerant then scroll through the list of almost 100 NIST refrigerants and select the refrigerant corresponding to the unit you will be servicing If you accidently select an incorrect refrigerant do not worry you can also change the refrigerant later in the readings screen Setting a refrigerant is mandatory before moving to the next screen WARNING Refrigerants classi...

Page 9: ...o Assign Detected Devices Now you are ready to connect your ManTooth PT Module to your current session To connect your module first tap on Devices None Specified this will take you to the next screen Tap on the ManTooth PT Module s that you wish to connect to your session from the list of devices that are displayed Remember your Module s name is the serial number printed on the main label and should...

Page 10: ...he appropriate time to connect your ManTooth PT Module to your system Connecting the ManTooth PT Module to the system before beginning your session will also ensure that the average minimum and maximum readings are accurate Readings The readings screen will display the pressures and temperatures as measured by the ManTooth PT Module display the liquid and vapor saturation values as well as calcula...

Page 11: ...based on the measured pressure and the refrigerant selected Temperature To assign temperature readings to either the high or low side simply tap on the box that contains the value you wish to assign and select the sensor that you want to assign to that spot Note the label on the ManTooth PT Module denotes which temperature port is T1 and which is T2 for easy reference Subcooling and Superheat To s...

Page 12: ...istory section on the app s home screen Any saved service data can be emailed from within Session History Other Buttons At the bottom of the readings screen there are two additional buttons The first is labeled Clear readings This will clear the minimum maximum and average readings of the session This function is especially useful for determining system stability The other option is Exit Session Th...

Page 13: ...vice Name Your ManTooth PT Module s name is displayed right on the label for easy reference The name takes the form of YJPT XXXX XXXX The device name serves as your ManTooth PT Module s name within the ManTooth RSA app its serial number as well as its Bluetooth name that will appear on your phone or tablet when pairing Temperature Probe Indicator On the label of the ManTooth PT Module T1 and T2 ar...

Page 14: ...nge instrument Sensing element 40 F to 266 F 40 C to 130 C Max Cord temp 176 F 80 C Max Clamp Temp 203 F 95 C Temperature Display Resolution 0 1 F or C Temperature Accuracy Instrument 0 2 C 0 36 F Working Temperature 4 F to 160 F Limited by battery Storage Temperature 4 F to 160 F For best battery performance do not store at over 100 F Working humidity 0 to 95 RH non condensing IP Class IP 50 Batt...

Page 15: ...er 50 times more refrigerant with each connection Pressure Zeroing Simple single button zeroing at the start of each session Elevation Compensation Enter elevation at the start of the session for effortless psia compensation Battery Rechargeable LiPo battery for long battery life and excellent recharging capability for the life of your ManTooth 15 ...

Page 16: ...l other YELLOW JACKET products included in this package are guaranteed to be free from material and workmanship defects for a period of one year These guarantees do not cover prod ucts that have been altered abused misused or improperly maintained 2014 Ritchie Engineering Co Inc 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com...

Reviews: