Ritchie YELLOW JACKET 39810 Manual Download Page 5

5  

 

Set Up Instructions 

To ensure quick, successful integration of the equipment  
into your shop, please follow these set-up procedures     
before the first use of the unit.   

1.  Check the oil drain bottle to ensure it is empty.  

2.  Check and open the valves on the storage tank. If     

the valve will not turn counter-clockwise and seems    
to be completely open, verify it is actually open by   
turning the valve clockwise one quarter turn. 

3.  Turn on the “Main Power Switch” at the upper left   

hand corner of the control panel. 

4. Turn 

scale 

on. 

5.  Press the “Tare “ key on the touch pad.                   

6.  Connect tank of virgin refrigerant to the (blue) low side 

hose using the provided tank refill adapter.  Remember 
to open the tank valve on the virgin tank. Turn the virgin 
tank upside down for the refill procedure. 

7.  Place selector switch in the “Recovery/Recycle”       

position. 

8.  Fill the storage tank on the unit with at least 10 lb. of 

refrigerant. This will insure a fast and proper charge. 

9.  Disconnect the tank of virgin refrigerant and press the 

“Tare “ key on the touch pad. 

10.  Fill vacuum pump with oil to the proper level (Models 

39810/39820/39822/39823 only). 

The RECOVER / RECYCLE function should be used to 
fully recover all refrigerant from an air conditioning         
system.  For instance, if the system needs to be opened   
to atmosphere to replace a part, all refrigerant must be      
removed before opening the system.  

Recover / Recycle Operational Steps 

 

1.  Connect the high and low side auto service hoses to 

the respective high and low side service ports on the 
automobile A/C system. Open the service hose valves. 

NOTE:  If desired, the gauges can now be used to aid 
investigation of an A/C system problem.  Ensure the 
automobile A/C system is turned off prior to running 
the unit. 

2.  Verify the automobile air conditioning system is off. 

3.  Turn on “Main Power Switch.” 

4.  Turn scale on—press the “TARE” key on the touch pad. 

5.  Place selector switch to the RECOVER / RECYCLE  

position. 

During the recovery operation, refrigerant is removed from 
both the high and low side of the automobile air condition-
ing system.  The LCD will display the amount of refrigerant 
being recovered.  

6.  When the unit achieves the proper vacuum level the 

RECOVERY COMPLETE LED will illuminate. 

7.  Monitor the unit for five minutes after the RECOVERY 

COMPLETE LED illuminates to insure that all of the 
refrigerant has been removed. 

8.  If the pressure rises above 0 psi, repeat steps 5-8. 

Note

: The vacuum cycle will not run if the system pressure 

is above 0 psi. 

9.  Press the OIL DRAIN switch for 10 seconds to drain oil 

recovered during the RECOVER / RECYCLE process. 

10.  Observe the amount of oil removed from  the auto A/C 

system. 

11.  After service has been performed make sure to inject 

the proper amount and type of oil back into the system  
(see oil injection procedure). 

 

Recover / Recycle 

Vacuum 

The vacuum function is designed to remove moisture from 
the automobile A/C system by pulling a deep vacuum.    
This mode is most often used after completing a repair 
which required opening the A/C system to the atmosphere.  
Moisture in an A/C system can cause erratic operation and 
must be removed before recharging the system with      
refrigerant.   

Vacuum Operation:    

Connect the high and low side auto service hoses to       
the respective high and low side service ports on the    
automobile A/C system. Open the service hose valves. 

NOTE:  If desired, the gauges can now be used to aid 
investigation of an A/C system problem.  Ensure the 
automobile A/C system is turned off prior to running 
the unit. 

3.  Verify the automobile air conditioning system is off. 

4.  Turn on “Main Power Switch.”  

5.  Place the selector switch in the VACUUM position.  

6.  Rotate the VACUUM TIMER to desired vacuum time. 

7.  When the VACUUM cycle is complete the timer knob 

will rotate to the off position.  

8.  Inject oil at this time (see oil injection procedure). 

NOTE:  

Always evacuate the A/C system for at least 15 

minutes to insure that you remove as much moisture and 
contamination as possible.   

Summary of Contents for YELLOW JACKET 39810

Page 1: ...1 Automatic Refrigerant Recovery Recycling Recharge Systems Models 39810 39811 for use with R 12 Models 39820 39821 39822 39823 for use with R 134a For Automotive Applications YELLOW JACKET...

Page 2: ...ety information may be obtained from refrigerant and lubricant manufacturers 800 Series Refrigerant Management Systems Section Page Section Page Specifications 2 Oil Injection 6 Safety Instructions 3...

Page 3: ...enting when disconnecting from the vehicle Use the Model 800 Series with the Specified Refrigerants Only See Specifications on page 2 for a list of compatible refrigerants Operate the Unit Within the...

Page 4: ...cale display and switches that control each of the unit s functions see page 6 13 High Pressure Gauge Shows the high side pressure of the automobile s A C system 14 Low Pressure Gauge Shows the low si...

Page 5: ...selector switch to the RECOVER RECYCLE position During the recovery operation refrigerant is removed from both the high and low side of the automobile air condition ing system The LCD will display th...

Page 6: ...an now be used to aid investigation of an A C system problem Ensure the automobile A C system is turned off prior to running the unit 2 Ensure that the automobile A C system is in a vacuum 3 Press the...

Page 7: ...ple R 134a The tank temperature is 75 F and the air purge indicator is reading 140 psi You should purge the storage tank until the air purge indicator reads 79 psi NOTE When reading the pressure tempe...

Page 8: ...n improper maintenance equipment abuse excessive contamination levels in refrigeration circuit improper voltage or acts of God YELLOW JACKET neither assumes nor authorizes any person to assume for it...