Ritchie WaterMaster Series Installation Instructions Manual Download Page 4

 

 

H. 

 

Hold-Downs

 - WaterMaster Fountains have mounting pockets 

molded into the base. Use of Ritchie stainless steel anchor bolts (not 

included) is recommended for concrete installations. Anchor bolts 

are available from any Ritchie authorized dealer, in packages of two, 

part # 16555.  

 

Once you have verified the positioning of the fountain, drill, 

install, and tighten down anchor bolts. Use the large washers 

provided to hold unit down. Tighten hold down anchors tight, but do 

not over tighten as this could damage the plastic feet. 

I. 

 

Assemble Valve  – 

Follow the steps to assemble the high 

pressure valve included with your waterer.

 

1.

 

Insert valve rubber into the valve rubber retainer.  

2.

 

Attach float arm to float as shown in diagram.  The raised 
emboss on top of float should be orientated as shown. 

3.

 

Screw thumb screw into cam arm.  To adjust water level, 
tighten thumb screw to lower, loosen thumb screw to 
raise. 

4.

 

Insert the valve rubber retainer into the valve body with 
the valve rubber up. Align the cam arm to the valve body 
and insert first pin. 

5.

 

Align the float arm and attached float to the cam arm and 
insert second pin. 

6.

 

For constant flow/trainer tube options: Drill a 1/8” hole 
in the threaded boss in the side of the yellow valve body. 
Attach petcock valve with thread sealant. 

J. 

 

Valve Mounting – 

After fountain is in proper place, place 

rubber washer, plastic washer and nut on bulkhead, cut hose to 

proper length and connect to valve bracket with hose clamp. Place the valve and bracket assembly in the slot 

provided in the wall of the valve chamber and tighten nut.  

K. 

 

Trainer Tube -

 The petcock valve outlet on WM54, 54D 90, & 96 has push to connect fitting for the plastic 

tubing for the water trainer. The other end of the tubing should be pushed tight into the hole provided in the wall 

of the valve compartment. The valve can be opened as desired to provide constant water flow.  The red plastic 

plug is to be used to plug the water trainer hole when not needed.  

L. 

 

Constant Flow (Optional) – 

With this constant flow fountain, overflow piping must be provided to remove 

the excess water from the fountain area. An end access opening is provided to aid in connecting drain piping from 

the overflow. A PVC pipe adapter is provided for the overflow connection. (See drawing on page 1.) The petcock 

valve is used to allow a continuous flow of warm water.

 

 

 

Valve Rubber 

WaterMaster Series Instruction Manual

3

31 August, 2019

Summary of Contents for WaterMaster Series

Page 1: ...watering fountain on the market This unit is built to give you excellent service when properly installed and maintained Please follow instructions carefully Read and understand all instructions before...

Page 2: ...ply line enters the fountain should be opposite of prevailing winter wind to give additional protection to the supply line B Water Supply Line The horizontal underground water line 1 should be sized t...

Page 3: ...QUALIFIED ELECTRICIAN IN COMPLIANCE WITH LOCAL CODES E Mounting Platform A concrete platform should be provided for all fountains It should be at least 4 thick and large enough to accommodate fountain...

Page 4: ...t second pin 6 For constant flow trainer tube options Drill a 1 8 hole in the threaded boss in the side of the yellow valve body Attach petcock valve with thread sealant J Valve Mounting After fountai...

Page 5: ...l against air infiltration before assembling Drop in the valve chamber cover Note Serial number or date code is found on underneath side of top red valve cover Tip You may use vegetable oil to fill th...

Page 6: ...e supply line down into the riser tube You may use nylon ties to anchor the cable to the supply line Both immersion heaters and supply line heaters are thermostatically controlled using power only whe...

Page 7: ...nel Rnd Hardware pkg 2 pkgs NS 18632 Cap for Trainer Hole 1 pkg 6 16464 Valve WM Assembly pkg 1 pkg NS 17173 Adapter 3 PVC 1 7 18314 Float with Hardware pkg 1 pkg NS 15931 Hose Clamp 1 SS 5 pkg 1 pkg...

Page 8: ...14866 Seal Foam 10 Roll 2 6 16464 Valve WM Asssembly pkg 1 pkg NS 18632 Cap for Trainer Hole 1 pkg 7 18314 Float with Hardware pkg 1 pkg NS 17173 Adapter 3 PVC 1 18313 Hardware for Float pkg 1 pkg NS...

Page 9: ...4 pkg 1 6 15377 Green Valve 3 4 Male pkg 1 pkg NS 14866 Seal Foam 10 Roll 2 7 18838 VLV HP Brkt Assy pkg 1 NS 18632 Cap for Trainer Hole 1 pkg 8 18314 Float with Hardware pkg 1 pkg NS 17173 Adapter 3...

Page 10: ...Panel Rnd Hardware pkg 2 pkgs NS 18632 Cap for Trainer Hole 1 pkg 6 16464 Valve WM Assembly pkg 1 pkg NS 17173 Adapter 3 PVC 1 7 18314 Float with Hardware pkg 1 pkg NS 15931 Hose Clamp 1 SS 5 pkg 1 p...

Page 11: ...are pkg 1 pkg NS 14866 Seal Foam 10 Roll 2 6 16464 Valve WM Assembly pkg 1 pkg NS 18632 Cap for Trainer Hole 1 pkg 7 18314 Float with Hardware pkg 1 pkg NS 17173 Adapter 3 PVC 1 18313 Hardware for Flo...

Page 12: ...18475 O Ring Valve Seal Pkg 4 pkg 1 6 15377 Green Valve 3 4 Male pkg 1 pkg NS 14866 Seal Foam 10 Roll 3 7 18838 VLV HP Brkt Assy pkg 1 NS 18632 Cap for Trainer Hole 1 pkg 8 18314 Float with Hardware...

Page 13: ...nty Effective September 2012 Ritchie Industries Inc warrants its products to be free of defective materials and workmanship Defective part s will be repaired or replaced at the option of Ritchie Indus...

Reviews: