C.
Riser Tube
– Install a riser tube (#4) around pipe to provide room for plumbing and to accommodate
optional shut-off valve. Ensure that the water supply line is centered in the riser tube. Do not add any insulation in
the riser tube, as it provides a path for frost. For optimum water line protection, use the 12” outside diameter
insulated Ritchie Thermal Tube. Use whatever combination of Thermal Tubes is required to reach at least 1'
below frost line.
Ritchie Thermal Tubes
18158 - 1’ top section
16612 - 4’ top section
16417 - 2’ top section
16416 - 2’ extension
NOTE:
The supply line touching the riser tube is the most common cause of the supply line freezing.
Do not surround the supply line with insulation, wood, or other foreign material. Any foreign material in
the tube may cause frost to migrate to the supply line causing it to freeze.
D.
Electrical Connection
(Optional) –
Although WaterMaster fountains will not require supplemental heat
when using constant flow, there are circumstances where supplemental heat may be required. If electricity is
available, it is a good management decision to run the electrical line for future use in the event your operation
changes and you choose not to constant flow.
WARNING: ANY ELECTRICAL SERVICE MUST BE INSTALLED AND MAINTAINED BY A
QUALIFIED ELECTRICIAN IN COMPLIANCE WITH LOCAL CODES.
E.
Mounting Platform –
A concrete platform should be provided for all fountains. It should be at least 4” thick
and large enough to accommodate fountain. An additional 4” high step 18” out from each side of the unit will
protect the unit from manure handling equipment, as well as discouraging animals from defecating in the
fountain. Extending the platform provides animals a place to stand while drinking, consider the size of your
animals when determining the dimensions of your platform. Slope the platform away from the fountain for
drainage. A rough broom finish on the concrete surface provides better footing for animals.
F.
Preparing the Bottom
- Apply the foam weather stripping to the bottom of the unit, around the outside edge
of the fountain.
G.
Position Fountain
- Connect hose to the top of the supply line, or the customer supplied shutoff valve at the
top of the concrete. Place fountain on the concrete platform over the riser tube so the supply hose is centered in
riser tube. Set the fountain on the concrete pad to inspect positioning of the installation. Once all connections are
lined up, marking anchor bolt location can easily be done with a drill.
NOTE:
Take this opportunity to check to see that the constant flow drain will align properly with the
drainpipe in the ground. (Some replacement installations may require additional fittings and elbows.)