SW2: Config
Switch
Description
Default
SW2 (1 - 2 )
(not relevant for
LightSYS which
is automatically
configured)
Defines the number of bus zones that the expander will support.
Number of Bus Zones
SW2 - 1
SW2 - 2
8 Off
Off
16
On
Off
24 Off
On
32
On
On
8 Bus Zones (Off,Off)
SW2 - 3
Defines which RISCO system
On
: LightSYS or ProSYS Plus
Off:
ProSYS (Bus zone configuration as per SW2 above)
SW2 - 4
Controls the configuration of the tamper terminals
On
: Tamper terminals shorted
Off
: Tamper terminals open. Use to connect a tamper switch
Off
Connectors Settings
Jumper
Function
Jumper
Function
J1
Quick Bus Connector to
bus zones bus
J2
Quick Bus Connector to
system main bus
LEDs
LED
Condition
Description
LD2
Device
Trbl
Indicates communication
between the BUS Zone
Expander and the bus detectors
On
: Communication OK
Flash
: Communication trouble between the zone expander and
any of the bus detectors or no bus zones defined for the BUS Zone
Expander
LD3
Power
Indicates communication
between the main panel and the
BUS Zone Expander
On
: Power and communication are OK
Flash
: Communication trouble between the BUS Zone Expander
and the main panel
Programming (ProSYS (P) and LightSYS (L))
The following instructions describe the procedure of allocating a bus detector using the BUS Zone Expander.
Note
: When using the Auto Setting feature (
P
:
[7] [5],
L
:
)
, the system will guide you th
r
ough the procedure mentioned below for a
maximum of eight ProSYS BZEs or four LightSYS BZEs.
Step 1: Adding the BUS Zone Expander
(not relevant for LightSYS)
1.
Access the Installer menu and select:
P
: [7] Accessories > [1] Add/Delete Module > [2] Zone Expander.
L
:
Install
Bus Device
Manual
Bus Zone Expander
2.
Use the (
P
)
and
or (
L
)
and
keys to position the cursor over the BUS Zone Expander
number for which you want to assign (or delete).
Note
: Make sure that the zone expander's physical ID dipswitch setting (SW1 1-3) is identical to the ID number you select during
programming.
3.
P (only)
: Place the cursor on the TYPE field
and use the
key to select:
BZE08: 8 Bus zones expansion
BZE24: 24 Bus zones expansion
BZE16: 16 Bus zones expansion
BZE32: 32 Bus zones expansion
Note
: Make sure that the zone expander type is set according to the one set by DIP switches SW2 (1-2).