background image

 
How to append a “prefix” or a “suffix” to the 

barcode data 

 

 

 

 

prefix 

 

suffix 

 

1.

 

scan above configuration code for Prefix or Suffix 

2.

 

enter the required values (right, numeric barcode) for Prefix or Suffix 

using the hex values for the desired HEX values from Prefix & Suffix 

TABLE (below page)” 

3.

 

then, end by scanning Code X (below, right) 

 

*

 

The max. of special characters is 5. 

*

 

When you append 1~4 required values for Prefix or Suffix, it must end 

with Code X. 

*

 

It doesn’t need Code X, if you append 5 values to barcode data. 

 

How to delete Prefix or Suffix 

1.

 

scan above configuration code for Prefix or Suffix 

2.

 

enter the “0” “0” (above, left) 

3.

 

then end by scanning Code X (below, right) 

 

Numeric barcode for settings 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Prefix & Suffix TABLE 

 

HEX 

HID 

(SPP) 

HEX  HID 

(SPP) 

HEX 

 

HEX    HEX    HEX   

01 

CTRL A 

(SOH) 

19  CTRL Y 

(EM) 

20  SPACE  38  8  50  P  68  h 

02 

CTRL B 

(STX) 

1A  CTRL 

Z(SUB) 

21 

39  9  51  Q  69 

03 

CTRL C 

(ETX) 

1B 

ESC 

(ESC) 

22 

“ 

3A  :  52  R  6A  j 

04 

CTRL D 

(EOT) 

1C  CTRL \ 

(FS) 

23 

3B  ;  53  S  6B  k 

05 

CTRL E 

(ENQ) 

1D  CTRL ] 

(GS) 

24 

3C  <  54  T  6C 

06 

CTRL F 

(ACK) 

1E  CTRL ^ 

(RS) 

25 

3D  =  55  U  6D  m 

07 

CTRL G 

(BEL) 

1F  CTRL _ 

(US) 

26 

3E  >  56  V  6E  n 

08  Backspace 

(BS) 

 

 

27 

‘ 

3F  ?  57  W  6F  o 

09 

Tab 

(HT) 

HEX  HID   

Only 

28 

40  @  58  X  70  p 

0A 

CTRL J 

(LF) 

80 

F1 

29 

41  A  59  Y  71  q 

0B 

CTRL K 

(VT) 

81 

F2 

2A 

42  B  5A  Z  72  r 

0C 

CTRL L 

(FF) 

82 

F3 

2B 

43  C  5B  [  73  s 

0D 

Enter 

(CR) 

83 

F4 

2C 

44  D  5C  \  74  t 

0E 

CTRL N 

(SO) 

84 

F5 

2D 

45  E  5D  ]  75  u 

0F 

CTRL O 

(SI) 

85 

F6 

2E 

46  F  5E  ^  76  v 

10 

CTRL P 

(DLE) 

86 

F7 

2F 

47  G  5F  _  77  w 

11 

CTRL Q 

(DC1) 

87 

F8 

30 

48  H  60  `  78  x 

12 

CTRL R 

(DC2) 

88 

F9 

31 

49  I  61  a  79  y 

13 

CTRL S 

(DC3) 

89 

F10 

32 

4A  J  62  b  7A  z 

14 

CTRL T 

(DC4) 

8A 

F11 

33 

4B  K  63  c  7B  { 

15 

CTRL U 

(NAK) 

8B 

F12 

34 

4C  L  64  d  7C  | 

16 

CTRL V 

(SYN) 

 

 

35 

4D  M  65  e  7D  } 

17 

CTRL W 

(ETB) 

 

 

36 

4E  N  66 

f  7E  ~ 

18 

CTRL X 

(CAN) 

 

 

37 

4F  O  67  g 

 

 

 

 

 

Barcode Configuration Method: 

(Flow chart for setup procedure :) 

 

 

 

 

 

Start 

Configuration 

Abort 

Configuration 

 

 

 

 

End 

Configuration 

 

 

 

 

READING MODE 

 

SINGLE SCAN 

 
 

SINGLE SCAN 

NO TRIGGER 

 

 

 

DOUBLE CHECK 

(ENABLE) 

 
 

DOUBLE CHECK 

(DISABLE) 

 

 

 

 

*

 

Double Check is used for determining if need to repeat the reading 
and decoding after successfully reading barcodes. 

 

SOUND LEVEL 

LOUDER 

 
 

MIDDLE 

 

 

 

LOWER 

 
 

SILENT 

 

 

 

 

*

 

control sound volume from louder to lower, even silent. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

%C%P%S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

%C%S%S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dem o 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dem o 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dem o 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

www.tec-it.com

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dem o 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dem o 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dem o 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

+%-$.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

+%-$.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

+%-$.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

MBA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

www.tec-it.com

MBB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

KJB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

KJA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

MCB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

MCG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

MCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Demo 

MCI

Summary of Contents for iDC9500

Page 1: ... put scanner in places excessively high temperatures such as expose under direct sunlight Don t use scanner in extremely humid area or drastic temperature change The rechargeable battery is permanently built into the product and cannot be replaced Never damage the rechargeable battery Damaging the casing of the rechargeable battery might cause an explosion or a fire Operating elements In the begin...

Page 2: ...re will not be LED indication when charging Reset Configuration to Defaults scan from A1 to A6 for HID profile or B1 to B5 for SPP profile HID profile SPP profile A1 B1 A2 B2 A3 B3 A4 A5 B4 Make sure you hear the beeper sound then scan next barcode to complete setting A6 B5 There are two operating modes on the scanner 1 Data Transmission mode Default It is a necessary to scan clean memory data whe...

Page 3: ... intervals among barcode data date time comma default FOR Android iOS use For example ABCD 01 23 2011 12 34 56 Tab FOR iOS use For example ABCD 01 23 2011 12 34 56 semicolon FOR Android iOS use For example ABCD 01 23 2011 12 34 56 Date and Time setting SET DATE Scan the SET DATE barcode then scan the six numeric digits in the format mm dd yy from the numeric barcode For example 01 23 2011 please i...

Page 4: ...7 3F 57 W 6F o 09 Tab HT HEX HID Only 28 40 58 X 70 p 0A CTRL J LF 80 F1 29 41 A 59 Y 71 q 0B CTRL K VT 81 F2 2A 42 B 5A Z 72 r 0C CTRL L FF 82 F3 2B 43 C 5B 73 s 0D Enter CR 83 F4 2C 44 D 5C 74 t 0E CTRL N SO 84 F5 2D 45 E 5D 75 u 0F CTRL O SI 85 F6 2E 46 F 5E 76 v 10 CTRL P DLE 86 F7 2F 47 G 5F _ 77 w 11 CTRL Q DC1 87 F8 30 0 48 H 60 78 x 12 CTRL R DC2 88 F9 31 1 49 I 61 a 79 y 13 CTRL S DC3 89 ...

Page 5: ...TALIAN PHARMACY DISABLE ENABLE CODE 93 DISABLE Symbologies On OFF 2 ENABLE CHINA POSTAGE DISABLE ENABLE UPC A DISABLE ENABLE UPC E DISABLE ENABLE MSI DISABLE ENABLE CODABAR DISABLE ENABLE EAN 13 DISABLE ENABLE EAN 8 DISABLE Demo 2 Demo 3 Demo 4 Demo MFC Demo MFB www tec it com MFA Demo AIL Demo AIK Demo AJL www tec it com AJK Demo BAL Demo BAK www tec it com BHJ Demo BHI Demo BIL www tec it com BI...

Page 6: ...ess inward firmly on the USB cover to reattach it Top Bottom Insert a thin object e g a bent paper clip into the small hole To click the reset button inside Quick guide is subject to change without notice R_180830_01 Pressing direction Reset ...

Reviews: