background image

11

Part 7  

PORTABLE CONTROL UNIT  FUNCTION 

A. 

Temperature Increase 

Button

C. 

Blower/Jet 

Massage Button

B. 

Temperature Decrease 

Button

D. 

Filter Button

E. 

Heat Button

G. 

Temperature Mode Button

F. 

LED Display

Functions of the Spa Portable Control Unit

•  LED Display: Once powered-up, the LED display will show the current water 

  temperature automatically.

•  ‘Temperature Adjustment’ Buttons (A & B): Increase (A) Decrease (B). Pressing one    

  of the temperature adjustment buttons will cause the LED display to flash. When  

 

  it is flashing, you can set the desired temperature. The value will increase or decrease    

  by 1°F/ 1°C for each press. If you hold the button for 2 seconds, the values will   

 

  increase/decrease rapidly.

  Temperature Adjustment Ranges: 86°F - 104°F/ 30°C - 39°C To lock the Portable 

  Control Unit, press (A) + (B) at the same time and hold them for 3 seconds. When the

  spa is left unattended please be sure to lock the Portable Control Unit to avoid having    

  the settings changed. Unlock the Portable Control Unit by pressing (A) + (B) at same time

  and holding for 3 seconds again.

• 

‘Temperature Mode’ Button (G): Press this button to change from Celsius to Fahrenheit.

• 

  ‘Jet Massage’ Button (C): Press this button to activate the Jet Massage system; when    

   activated a green indicator light turns on. It can be turned off by pressing it again.

NOTE:

•  The massage system will stop automatically after 15 minutes of operation. Re-activate    

  the jet function by pressing the jet button again.
•   When the filter mode is on, pressing the Jet Massage Button (C) will cause the filter  

 

  mode to turn off and the jet massage mode to turn on.
•   Heating and jet function can not be activated at same time. When heating system  

 

  is working, pressing (C) will change heating mode into jet mode: heating and filtering  

 

  are shut down, jet system is activated. If you press (C) again, heating and filtering  

 

  mode will re-start.
•  Pressing Filter Button (D) activates the filter system. This button turns the filter pump on   

  and off. The green indicator light will turn on when the filtration system is activated. 

  Note: When heating and filter functions are working at same time, pressing (D) will shut

  down heating and filtering together. When (C) is on, filter and heating cannot be 

  activated, therefore (C) should be shut down first.
•   Pressing the Heat Button (E) activates the heating and filtering system at the same time.   

  The green filter light and red heat light will be activated at the same time. The    

 

  Portable Control Unit does not stop heating until the current water temperature   

 

  reaches the set temperature indicated by the ‘blinking’ red light. 
•  When you press the Blower Button (C) the circulation pump and the heater will stop, as
  a consequence the temperature on the display will decrease (due to no flow of water
  between the Portable Control Unit and the spa). To regain heating functionality turn  

 

  the Blower Button (C) off and press the Heat Button (E). The circulation pump will restart   

  and the temperature will increase or the heating mode will restart automatically after the 

  water temperature drops 1°F/ 1°C (approx) below the set temperature. Max. heat 

  temperature: 104°F (39°C). Allow 24-48 hours to heat up your spa.

Summary of Contents for CSCHTRG29

Page 1: ...1 P O R T A B L E S P A Rio Grande w w w c a n a d i a n s p a c o m p a n y c o m Rio Grande Spa P O R T A B L E 110 115V 60Hz 15 amp Read this manual before operation...

Page 2: ...NG RISK OF ELECTRIC SHOCK DO NOT BURY CORD Ensure the electrical cord is located away from lawn mowers hedge trimmers and other equipment Reduce the risk of electric shock by replacing damaged cords i...

Page 3: ...e defective during this period Canadian Spa Co will repair or at its option replace the defective spa bladder without charge to the customer Plumbing Warranty Canadian Spa Co warrants the plumbing of...

Page 4: ...that all the following key components are present Box Includes A Spa Liner with integrated Control Unit Connectors B Inflatable Cover Lid C Portable Control Unit PCU with GFCI Plug D Thermal Ground S...

Page 5: ...34kg c 85lbs 38 5kg 27 5 x 21 5 x 23 5 69 5 x 55 x 60cm CE GS CETL ETL 1 5 2 F hr 1 Site Selection IMPORTANT Before you position inflate and fill with water follow these instructions 1 Place in an ar...

Page 6: ...NG RISK OF ELECTRIC SHOCK The GFCI plug must be tested before each use Do not use if GFCI test fails 1 Insert the plug into the power outlet 2 Press the RESET button the indicator light turns red 3 Pr...

Page 7: ...end Please do not over tighten and check that the Connection Hoses are straight and not kinked Align the connectors to the Portable Control Unit with the appropriate input ports on the spa as highlig...

Page 8: ...counter clockwise and release the air until the water is coming out then screw the air valve clockwise tightly Use a towel to dry off the pump Fig A Thermal Blanket Place Thermal Blanket on water surf...

Page 9: ...spa chemicals Please pay attention to the chemicals used and dosage Spa damage resulting from misuse of chemicals is not covered by the warranty Water Balance We recommend you maintain your water bala...

Page 10: ...rol Unit remove the filter cartridge from the Filter Housing and dry the Portable Control Unit by draining all water from Portable Control Unit body and pipes Open the Drain Valve on the bottom of the...

Page 11: ...is on pressing the Jet Massage Button C will cause the filter mode to turn off and the jet massage mode to turn on Heating and jet function can not be activated at same time When heating system is wor...

Page 12: ...er is over 122F 50 1 Unplug the GFCI cable from the outlet 2 See Part 9 Spa Operation Check List for possible solutions 3 Power on spa again to see if error is resolved if not please contact for servi...

Page 13: ...ports inside the tub are clean and remove any obstructions detected Check if this resolves the pump s malfunctioning CHECK 5 Check Filter Is clean Check the filter If the filter is dirty or scaled wa...

Page 14: ...ridge Improper chemical treatment Do filtration longer and more frequently Clean replace the filter cartridge Change the spa water completely Refer to the chemical manufacturer s instructions Red Ligh...

Page 15: ...a Pillow Pillow attaches to the perimeter rim of portable spa Round 7 Cover Cap Waterproof tough durable Prevent cover colour bleaching Resists UV damage Elastic sewn into 12 30 5 cm hemmed skirt for...

Page 16: ...ost Code 201205 Tel 86 21 58942200 Fax 86 21 58940305 www canadianspacompany com Disclaimer Canadian Spa Co or any of its authorized service technicians shall not be held liable for injury inconvenien...

Reviews: