background image

 

(L003-507) 

Reference Manual

 

 
 
 

Summary of Contents for axleWEIGHr

Page 1: ...L003 507 Reference Manual...

Page 2: ...in order to improve design performance or reliability The information in this manual is believed to be accurate in all respects at the time of publication but is subject to change without notice Rins...

Page 3: ...13 Dynamic Scale Creating Setting up Trucks 9 1 14 Setting Time Date 10 1 15 Stability 11 1 16 Traffic Lights 12 1 17 Clicker Operation 13 1 18 USB Operation 14 1 19 Printer Operation 2 SETTING UP TRU...

Page 4: ...cific application The discard timer allows for weighing first then setting up the truck id The farm configuration data can be setup to individual trucks for unique data basing options Many of the feat...

Page 5: ...Operator Manual Rev 2 01 L003 507 V1 2 1 Page 3 User Interface and Display Code Description 1 Display 2 Numeric Keypad 3 Function Keys Fixed 4 Power Key...

Page 6: ...function not available 8 Secondary Display totalised weight of last truck 1 6 Primary Annunciators Symbol Name Description HOLD Visible when the displayed reading is held NET Visible when the displaye...

Page 7: ...s most useful where strings are small and contain no lowercase or unprintable characters The available characters are printed in orange on the keypad Code Description 1 Number Buttons 0 9 short press...

Page 8: ...pt changes and finish Long press of cancel Cancel and exit without changes Cancel Delete character Up Down Move cursor Long press of down Delete string after cursor Switch editing modes 1 9 Turn Instr...

Page 9: ...shown below 110 VAC 240 VAC accepted AC POWER MAIN CONNECTIONS Grey Terminal Black HOT Connector 1 Scale Cable 5 pin White Terminal White Neutral Connector 2 Remote Display Green Terminal Green Groun...

Page 10: ...13 201 1 12 Zero Key When an empty scale has drifted away from a true zero reading this key is used to perform a zero adjustment on the scale display The zero adjustment is stored when power is remove...

Page 11: ...eighments using this formula K R D K Known weight of truck reference R Average reading of 5 weighments from axleWEIGHr axle scale D Dynamic Scale Adjustment 1 Press and hold F2 for 2 seconds to enter...

Page 12: ...weight if one pass Farm Field selection will then prompt see section 2 10 2 Editing Truck Data existing Select the truck you want to configure Proceed through the rest of the prompts Press cancel key...

Page 13: ...trucks in the truck database Alternately use the key fob Setting up Farm Field F1 These options are associated with the Truck key and allow different fields to be assigned to different trucks Note If...

Page 14: ...Lights While at Zero stable weight the traffic lights should both be off There are various conditions that will activate the lights If there are errors the RED light will activate See table below TRA...

Page 15: ...Config menu Long press of F2 and go to KEY BIND menu Press OK to enter learn mode Once key fob has been press DONE will display Weigh in 2 PASS Weigh out pre set tare 1 PASS Weigh out 2 PASS These ar...

Page 16: ...al log file will remain on the console FROM USB This means you will duplicate the files from the USB drive If you have modified the truck csv file or the harvest csv file then they will overwrite your...

Page 17: ...01 L003 507 V1 2 1 Page 15 Ensure tension spring is configured for maximum tension as shown above to ensure optimal printing operation There is a PRINT test button shown in figure above used to perfo...

Page 18: ...ight mode The Cancel key C or OK key allows you to cancel out of the weigh out mode and return to normal mode without clearing the first weight or adding any weight to totals 1 22 Weighing first then...

Page 19: ...Operator Manual Rev 2 01 L003 507 V1 2 1 Page 17...

Page 20: ...settings TRUCK F1 A short press of the truck button will allow you to select from your list of permanent trucks Use the arrow keys to select truck Short press select of truck Long press configure tru...

Page 21: ...Operator Manual Rev 2 01 L003 507 V1 2 1 Page 19 To re bind all wireless key fobs or to change the farm field selection methods see end of manual...

Page 22: ...This information should be setup and edited as new farms fields are added or removed These should all be typed in capital letters The R423 display is optimal with upper case lettering Description Map...

Page 23: ...ble Id Truck Column Id and truck needs to unique and will display to the R423 screen print on the ticket The id number should be sequential and in order Example 1 2 3 4 etc The labels in the truck col...

Page 24: ...e log csv file contains all of the weight data for each truck including the farm and field configuration A farm field that does not have data details is due to the farm field not configured The truck...

Page 25: ...AD The weight is above the maximum allowable weight reading Warning overloading may damage mechanical scale elements Check the condition of load cell connections Check for damaged load cell ERROR RANG...

Page 26: ...scaling factor for in motion calibration adjust Zero zero calibration capture do not use Span span calibration capture do not use MvV raw millivolt reading from scale base example 2234 0001 Note to e...

Page 27: ...423 instrument and up to the entire axleWEIGHr box including kiosk printer R423 This is the stainless indicator mounted on the front of the axleWEIGHr LUA The lua module is located on the back of the...

Page 28: ...om global all trucks assigned to multiple each truck is assigned to a single farm and field Press OK Key to enter Menu Use up down arrow keys to switch from GLOBAL to MULTIPLE Press OK to make Selecti...

Page 29: ...Notes...

Page 30: ......