Rinnai Rack Installation
Electrical (Pre-Wired Electrical Assembly)
1. Locate gang box on side of TRS frame.
2. Remove the 2 screws securing front panel to gang
box.
3. Remove front panel.
4. Run building supplied electrical wiring and conduit
to gang box.
5. Connect building wiring to the 3 12AWG, THHN
wires, Hot (Black), Neutral (White), and Ground
(Green).
6. Reinstall front panel to gang box using 2 screws.
INTERIOR MODELS AVAILABLE WITH
ELECTRICAL ASSEMBLIES:
TRS03ILW TRS03IL TRS03 TRS04
TRS36 TRS46
TRS05 TRS06
4 Unit Electrical Assembly with (2)
20A, 125V, 2-Pole, 3 Wire
Grounding Receptacles.
6 Unit Electrical Assembly with
(3) 20A, 125V, 2-Pole, 3 Wire
Grounding Receptacles.
Electrical Assemblies are installed on the middle rack
frame of the following indoor racks for single point
electrical connection.
Conduit
Punch-out
Green
(Ground)
Black
(Hot)
White
(Neutral)
WARNING
Shut off building supply power prior to connecting to
TRS electrical assembly. Failure to do so may result
in property damage, bodily harm, or death.
IMPORTANT:
Refer to the
Specifications
sections in
this manual for electrical requirements.