background image

Rinnai Smart Cylinders low-medium pressure indoor stainless steel: Owner and installer guide: 20432-A 01-15   |   17

Electrical supply and connections

The electrical connection must be carried out by a qualified person in accordance 

with NZ Electrical Regulations. The water heater must have the heating element 

connected to an independent, fused, AC 230 V 50 Hz power supply with an isolating 

switch installed at the switch board. Disconnect all power prior to installation and 

commissioning.

•  The water heater must be filled with water prior to connection to the power supply
•  Household wiring to the heater must be capable of withstanding the appliance load
•  Fixed wiring must be protected from contact with the internal hot surface of the water 

heater

Electrical access is via a hole in the element cover for mounting with an approved electrical 

conduit gland. For entry to the element cover remove the two fixing screws.

Connect all Live, Neutral and Earth wires in accordance with the wiring diagram. Inspect and 

ensure all wiring links are secure prior to fixing the access cover and turning the power on.

To ensure the over-temperature and energy cutout is set press the ‘reset’ button on the 

thermostat.

The appliance is intended to be connected to cables of fixed wiring which has a cross-sectional 

area of 1.5 mm

- 2.5 mm

2

.

A

N

Element

Thermostat

Terminal Block

brown

blue

green/yellow

green/yellow

Summary of Contents for Smart Cylinders

Page 1: ...steel Owner and installer guide Models Rinnai Smart Cylinders Low medium pressure duplex stainless steel LS13555030S LS18055030S LS25055030S Hello installer Please leave this guide with the home owne...

Page 2: ...maintenance can cause property damage personal injury or loss of life The appliance is not to be used by persons including children with reduced physical sensory or mental capabilities or lack of expe...

Page 3: ...lation Specification summary 12 Dimensions 13 Plumbing setup 14 Storage and delivery temperatures 15 Water quality 16 Electrical supply and connections 17 Valves and fittings 18 Commissioning 18 Limit...

Page 4: ...will automatically adjust the cylinder heating times according to your hot water usage pattern A certain amount of hot water is guaranteed at all times depending on the level you select Manual mode P...

Page 5: ...ter temp in cylinder 1 50 C 2 55 C 3 60 C 4 65 C 5 70 C Biosafe operation To meet the New Zealand Building Code requirement1 to disinfect water for legionella bacteria2 the system will perform heating...

Page 6: ...e fitted and are in working order It is also important that you do not tamper or remove any of these devices Your hot water system has an energy cutout thermostat The operation of this thermal cut out...

Page 7: ...hard water areas the element s must be periodically descaled To do this the unit must be drained and the element s removed Rinnai has a maintenance service and spare parts network with personnel who a...

Page 8: ...same time for more than three seconds I have cold water while in iQ automatic mode A sudden significant increase of hot water consumption may generate occasional cold water Change to manual mode and...

Page 9: ...small quantity of water through the drain line If water is discharging continuously there may be a fault with one of the valves contact the installer to discuss Water is too hot If possible check the...

Page 10: ...This page intentionally left blank...

Page 11: ...Installation Installation servicing and repair shall be carried out only by authorised personnel...

Page 12: ...r also needs to be oriented so that the control is in a position where the homeowner can easily see and access it Operating pressures Maximum inlet pressure 120 kPa Maximum working pressure 120 kPa El...

Page 13: ...d inlet eco solar Top view Element Side cold inlet bottom cold inlet top outlet all sizes 45 45 Dimensions Tank size A mm B mm C mm Height mm Diam mm 135 L 320 N A 335 1015 550 180 L 320 465 335 1295...

Page 14: ...l of our Stainless Steel cylinders are super light At under 55kg each one burly plumber can transport carry and install them easy Show us your muscles www youtube com RinnaiNZ I www facebook com rinna...

Page 15: ...pipe work should be insulated with polythene foam or equivalent insulation to optimise performance and energy efficiency To prevent damage to the water heater when attaching pipe clips or saddles to t...

Page 16: ...ality and filtration experts be undertaken Hard water Hard water containing calcium carbonate can cause scaling on hot surfaces We recommend a water temperature of no more than 65 C to minimise scale...

Page 17: ...er must be capable of withstanding the appliance load Fixed wiring must be protected from contact with the internal hot surface of the water heater Electrical access is via a hole in the element cover...

Page 18: ...ach tap when the water runs freely without air bubbles 4 Check all plumbing connections and pipe work for water leaks 5 Switch on the electric power supply To turn off the water heater It may be neces...

Page 19: ...rranty period Warranty All components Up to 1 year Replace or repair free of charge the cylinder and or part if it fails due to faulty manufacture Inner cylinder Years 2 5 inclusive Replace or repair...

Page 20: ...anufacturer s instructions 4 The warranty applies only to the components supplied by Rinnai It does not apply to components supplied by others such as but not limited to these isolating valves electri...

Page 21: ...Rinnai 5 Where the cylinder has failed directly or indirectly as a result of poor water quality outside the limits specified 6 Where it is found that there is no fault with the cylinder and the issue...

Page 22: ...inner cylinder and causes damage to carpets and flooring 11 months Yes No Cost of cylinder replacement covered by Rinnai Consequential loss damage to carpets and flooring is not1 Inner cylinder fails...

Page 23: ...01 15 23 Please keep these details in a safe place for future reference ATTACH YOUR PROOF OF PURCHASE HERE RECORD YOUR details OF PURCHASE BELOW Retailer Retailer address Date of purchase Product deta...

Page 24: ...Rinnai co nz Experience our innovation 0800 746 624 http www youtube com rinnainz http www facebook com rinnainz 20432 A...

Reviews: