Heavy pipe connect ion could cause abnormal combust ion, explosion or
fire by leakage could appear.
If you do not fix kettle legs, product might be shaken when kettle is being
WARNING
rotated. That could lead food such as broth overflowed causing a burning.
Pipe connection would be under a lot of pressure so that product could be
damaged causing fire, or explosion by leakage.
Page 12
When you install product, distance from inflammables.
-
If surrounded walls are composed of inflammables, have enough space as t he followings.
Dist ance from sidewall t o product : more t han 50cm
Dist ance from rear wall t o product : more t han 60cm
Dist ance from t he ceiling t o product : more t han 150cm
Also, it is a must t o inst all noninflmmables such as exhaust hood for vent ilat ion.
-
If product and wall is t oo close, fire could happen. Also, if you at t ach st ainless st eel plat e, general
plat e on t he wall composed of inflammables, fire could t ake place or wall might be damaged due t o
heat t ransmission.
-When you inst all t he heat -resist ant plat e, you should have a dist ance more t han 3cm from t he heat -
resist ant plat e t o t he inflammable wall.
Material
Thickness
Warning
St ainless st eel plat e
More t han 0.3mm
St eel plat e
More t han 0.3mm
More t han 3cm from t he inflammable wall
Reinforcement is needy t o prevent deformat ion.
The inst allat ion/ product ion of heat -resist ant plat e should be implement ed according t o t he
const ruct ion of t he kit chen. And Rinnai is not responsible for t he cost .
Do not at t ach supplement s around t he product aft er inst allat ion. It could cause fire.
The distance from the floor to the ceiling must be at least more than 150cm.
MUST DO
In order t o open ket t le lid, t he space must be obt ained minimum 150cm.
Remove surrounding inflammables.
MUST DO
It might cause fire.
When you install more than 2 products, keep a distance of 30cm above
between products.
MUST DO