HOME OWNER / INSTALLER

FOR YOUR SAFETY

THIS MANUAL MUST BE READ IN ITS

ENTIRETY BEFORE OPERATING HEATER

RHFE-1004FA

ENERGYSAVER

GAS DIRECT VENT WALL FURNACE

Conversion Manual

WARNING:

IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED

EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY

DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS

AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

WHAT TO DO IF YOU SMELL GAS

DO NOT TRY TO LIGHT ANY APPLIANCE.

DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY PHONE

IN YOUR BUILDING.

IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR'S

PHONE.  FOLLOW THE GAS SUPPLIER'S INSTRUCTIONS.

IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE

DEPARTMENT.

INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED

INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.

This appliance may be installed in a after market permanently located,

manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the Rating Plate.

This appliance is not convertible for use with other gases, unless a certified kit

is used.

INSTALLER: MUST LEAVE MANUAL WITH UNIT AFTER INSTALLATION.

OWNER: RETAIN THIS MANUAL SAFELY, FOR FUTURE REFERENCE.

Summary of Contents for RHFE-1004FA

Page 1: ...ICAL SWITCH DO NOT USE ANY PHONE IN YOUR BUILDING IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR S PHONE FOLLOW THE GAS SUPPLIER S INSTRUCTIONS IF YOU CANNOT REACH YOUR GAS SUPPLIER CALL THE FIRE DEPARTMENT INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER SERVICE AGENCY OR THE GAS SUPPLIER This appliance may be installed in a after market permanently located manufactured mob...

Page 2: ...00 8 400 HIGH 30 720 29 200 NAT QTY 2 1 PARTS No LPG HI LOW 1004F 2031 B 1 80 1004F 2036 B 1 95 QTY 2 1 PARTS No 1004F 2031 A 0 95 1004F 2036 A 1 20 RHFE 1004FA P Normal Altitude RHFE 1004FA P High Altitude RHFE 1004FA N Normal Altitude RHFE 1004FA N High Altitude MODEL GAS TYPE DIAMETER OF ORIFICES INCHES mm DAMPER ADJUSTMENT LPG NAT 0 037 0 95 0 047 1 20 10 10 10 10 10 10 0 071 1 80 0 077 1 95 7...

Page 3: ...n damage to the unit If you have not been properly trained on converting this product please do not proceed Contact a qualified service agency to perform conversion 5 Propane gas unit air shutter settings Loosen set screw on air adjustment rods Adjust all three air shutters to 100 air no notches will be showing on the rods when adjusted correctly The air rods can be found directly under each gas l...

Page 4: ... the SW1 switch again and change to Low pressure mode PL will be indicated on the display 9 Record your pressure reading on your manometer If the Low fire pressure needs adjusting this can be achieved by pressing the button to decrease the pressure or the button to increase the pressure Set unit to correct pressure as shown the Technical Data 10 Press the Economy button the LED will then display 1...

Page 5: ...3 Press the Economy button to enter the high fire pressure into memory The LED display will indicate 78 14 Press the ON OFF button again The LED display turns blank and the unit returns to the normal OFF mode 15 Reconfirm all pressure settings before putting said unit back into operation Next disconnect your manometer from the unit and reinstall the 1 8 test port plug Leaks test all connections on...

Page 6: ...BAS 8 400 8 400 HAUT 30 720 29 200 NAT QUANTITÉ 2 1 NUMÉRO DES PIÉCES LPG HAUT BAS 1004F 2031 B 1 80 1004F 2036 B 1 95 QUANTITÉ 2 1 NUMÉRO DES PIÉCES 1004F 2031 A 0 95 1004F 2036 A 1 20 RHFE 1004FA P Altitude Normale RHFE 1004FA P Haute Altitude RHFE 1004FA N Altitude Normale RHFE 1004FA N Haute Altitude MODELE TYPE DE GAZ DIAMETRE DES ORIFICES EN POUCES mm REGLAGE AMORTISSEUR LPG NAT 0 037 0 95 0...

Page 7: ...onvenablement formé pour convertir cet appareil veuillez ne pas poursuivre Contactez une société de service compétente pour réaliser la conversion 5 Réglages des volets d aération pour les appareils à gaz propane Desserrez la vis sur les tiges de réglage d air Réglez les trois volets d aération à 100 d air aucun cran n apparaîtra sur les tiges une fois le réglage fait correctement Les tiges d air ...

Page 8: ...PL va s afficher à l écran 9 Enregistrez la lecture de pression sur votre manomètre Si la pression Feu Bas a besoin de réglage ceci peut être réalisé en appuyant sur le bouton pour réduire la pression ou le bouton pour augmenter la pression Réglez l appareil à la pression correcte comme il est indiqué dans les Données Techniques 10 Appuyez sur le bouton Economie Le LED affichera alors 18 indiquant...

Page 9: ...ez sur le bouton MARCHE ARRET de nouveau L écran LED devient vierge et l appareil retourne à une position ARRET normale 15 Reconfirmez tous les réglages de pression avant de remettre l appareil en question en marche Puis débranchez le manomètre de l appareil et réinstallez la prise de test de 1 8 Faites un test de fuite sur tous les branchements une fois que le processus de conversion a été accomp...

Page 10: ... High Injecteur haut Injector Low Injecteur bas Injector High Injecteur haut Injector Low Injecteur bas Conversion Plate Plaque de conversion Conversion Plate Plaque de conversion Visual Reference Référence visuelle Qty Quantité Gas Gaz Part No Numéro de piéce Part Name Nom de la piéce LIST OF CONVERSION PARTS LISTE DES PIECES DE CONVERSION ...

Page 11: ... 10 MEMO ...

Page 12: ...1004F 2092 02 03 Printed in Japan 2005 05 ...