background image

En

g

lis

h

h

Fig. 1 

Always mount the extractor hood over the center of
the hob.

Ensure that the appliance is installed in a location

with good and permanent ventilation.

When making the electrical connections, check that

The  mains  voltage  and  frequency  corresponds
to   the   technical   information   shown   on   the
rating plate.

Electrical  connection  must  be  made  in
accordance  to  local  standards  only.  Check  that
the voltage   in   your   area   is   correct   before
plugging in.

Use an electrical connector with earth that is correct
for your location. The electrical connection of this
appliance must be connected to earth (w

here

applicable)

:

Green  &  Yellow  =     EARTH;  Blue  =  NEUTRAL;
Brown =LIVE

Ducted mode:

Connect the extractor hood to the exhaust duct
through  a  pipe  of  minimum  Ø160mm.  Use  the
shortest and straightest duct route possible.

Do  not  connect  the extractor  hood  to  exhaust
ducts carrying combustion fumes.

Arrange proper ventilation if the extractor hood
is  used  in  conjunction  with  other  appliances
which are not supplied by electrical power e.g.
gas burning appliances. The kitchen must have a
direct opening to the outside in  order to allow
entry of fresh air.

Note: 

The manufacturer accepts no responsibility for 

complaints attributed to the design and layout of the 
pipe work. 

Do  not  flambé  or  grill  with  an  open  flame  directly
under the extractor hood. Flames could  be drawn  up
into  the  hood  by  the  suction  and  the  grease  filters
may catch fire.

Monitor  cooking  continuously  as  overheated  oil
increases the risk of self-ignition.

Do  not  operate  the extractor  hood  without  a  grease

filter.

It  is  important  to  clean  and/or  replace  the  filters  at
appropriate intervals.

Grease deposits build-up increases the risk of fire.

Always  disconnect  the  unit  from  the  power  supply
before carrying out any cleaning or maintenance work
on the hood.

Ensure that the power supply chord is free from any
heat source or sharp objects.

Multiple plugs and extension cables must not be used.
Overloading is dangerous and may cause a fire hazard.

Disposal

 

This  appliance  and  its  packaging  are  environmentally
friendly and recyclable. Please help us to care for the
environment  by  disposing  the  packaging  in  a  proper
manner and recycling any old appliances.

Before disposing  an  old  appliance,  disconnect it  from
the  power  supply  and  cut  the  power  supply  cord  to
prevent hazards.

The  manufacturer  will  not  be  held  liable  for  any 
damages  resulting  from  improper  installation  nor 
failure  to  adopt  proper  safety  measures  during 
installation and operational use of the appliance. 

Summary of Contents for RH-C819-GB

Page 1: ...English Operation Installation Manual Chimney Hood RH C819 GB RinnaiCorporation ...

Page 2: ...TABLE OF CONTENTS English Version 2018 08 Page 1 7 ...

Page 3: ...h the instruction CAUTION Accessible parts may become hot when used with cooking appliances The appliance uses 4 hob elements at most Unpacking Do not use the appliance if there are obvious signs oftransportationdamage If the power supply cord is damaged it must be replaced by the manufacturer its service agent or qualified technician to avoid hazard Please ensure that young children do not play w...

Page 4: ... accepts no responsibility for complaints attributed to the design and layout of the pipework Do not flambé or grill with an open flame directly under the extractor hood Flames could be drawn up into the hood by the suction and the grease filters may catch fire Monitor cooking continuously as overheated oil increasesthe risk of self ignition Do not operate the extractor hood without a grease filte...

Page 5: ...n W x D x H Note The manufacturer reserves the right to change any technological improvement or modification without prior notice Fig 2 COMPONENTS Re Qt Productcomponents A 1 Mountingbracket B 1 Inner duct C 1 Outerduct D 1 Motorhousing E 3 Bafflefilter Qty Installation components 2 Screw M3 x 12 4 Screw ST5 x 25 Qty Documentation 1 Operation InstallationManual Fig 3 ...

Page 6: ...sweight Draw a vertical line at the center of the wall From bench top see A draw a horizontal line see B above minimum installation height level Mark a reference point at C Repeat this step on the otherside Drill Ø 8mm holes at center of marking points Insert wall plugs in the wall Fix the hood body to wall using 2 two ST5 x 25 screws provided Tighten screws firmly Note Adjust the hood body alignm...

Page 7: ...e recommend you to switch on the blower a few minutes before starting to cook Leave it on for approximately 15 minutes after cooking or till all cooking smell is completely removed Switch control Touch the sensor buttons gently to operate this appliance A B C E F A On Off Switch B Display Window C Fan Speed increase D Fan Speed decrease E Delay Timer F Light 1 When power up the hood the orange rin...

Page 8: ...ter 5 seconds all lights will turn off The timer will blink and the ON OFF icon will indicate with an orange ring backlight To disable press the ON OFF icons All function icons will light up Press the timer icon to disable 9 When the cooker hood has been operated for 90 hours an orange dot indicator will blink at the bottom right of the display square This indicator is to remind you to clean greas...

Page 9: ...hand soak the filters in warm detergent solution to ease the removal of grease Brush the filters rinse thoroughly and leave it to dry before refitting If by dishwasher select an appropriate wash program Leave it to dry before refitting Note slight discoloration of the filter may occur Charcoal filter where applicable Fig 12 The charcoal filter should be replaced when it is dirty or discolored or w...

Page 10: ...charcoal filters for settingin recirculation mode Motor is running but no airflow Poorexhaust PleasecontactRinnai CustomerCareService Whirringsound Foreign object may be in contact with fan blade PleasecontactRinnai CustomerCareService Lights are not working Bulbs are blew out Replacethe damaged bulbs Bulbsare loose Tighten the bulbs English If problem persists after the above checks please contac...

Page 11: ...cha Thewa Bangphli Samutprakarn 10540 Thailand 澳門青洲跨境工業大廈3樓F座 บร ษท ร นไน ประเทศไทย จ า กด Phone電話 853 2852 7799 Fax 傳真 853 2827 0572 URL 网址 www rinnai com hk mo เลขท 61 1ซอยก งแกว 9ถนนก งแกว ต า บลร ช า าเทวะ อ เา ภอบ างพ ล จงหวดสม ทรปร าก ร า ประเทศไทย10540 Tel 66 2 3124330 40 Email lucky02 luckyflame co th URL www luckyflame co th Malaysia Rinnai M Sdn Bhd D2 3 G D2 3 1 Block D2 Pusat Perdagang...

Reviews: