34
GAS PRESSURE SETTING
The working gas pressure on the water heater is electronically controlled and factory set. Under normal
circumstances it
does not require adjustment during installation
. The pressure should be checked
when the unit is installed and each time it is serviced to ensure that it is correct.
Contact Rinnai before attempting to alter the gas pressure if you are unsure of what to do.
Incorrect adjustment can void the warranty.
1. Turn 'OFF' the gas supply.
2. Turn 'OFF' 230V power supply.
3. Remove the front cover from the appliance.
4. Check gas type switches no.1 and no.2 of Dip SW2 are in the correct position for the type of gas
used. See Fig. 1
5. Attach pressure gauge to burner test point. (Fig. 2)
6. Turn 'ON' the gas supply.
7. Turn 'ON' 230V power supply.
8. If remote controllers are fitted, turn the unit 'ON' at the controller and select a maximum delivery
temperature.
9. Open a hot water tap fully.
(CAUTION: Ensure building occupants do not have access to hot
water outlets during this procedure.)
Wait for the unit to light.
* Simply changing the position of the dip switches will not convert the
unit from one gas type to the other. The conversion procedure requires
a change of injector manifold. Contact Rinnai or your supplier.
NOTE
32 liters
26 liters
Burner
test point
Dip SW1(8P)
Dip SW2(6P)
Dip SW2
Summary of Contents for REU-VR2632FFUD - 26i
Page 20: ...20 OPERATION HD50e 26i HD50i...
Page 21: ...21 OPERATION HD70i AC 230V AC 230V HD70e...
Page 38: ...38 DIMENSIONS HD70e...
Page 39: ...39 DIMENSIONS HD70i...
Page 40: ...40 DIMENSIONS HD50e...
Page 41: ...41 DIMENSIONS 26i HD50i...
Page 44: ...44 FLOW CHART 26i HD50e HD50i HD70e HD70i...
Page 45: ...45 WIRING DIAGRAM HD70e HD70i...
Page 46: ...46 WIRING DIAGRAM 26i HD50e HD50i...
Page 47: ...47 DIAGNOSTIC POINTS HD70e HD70i 26i HD50e HD50i...
Page 48: ...48 WATER FLOW CHARACTERISTICS 26i HD50e HD50i HD70e HD70i...
Page 49: ...49 LETTER OF COMPLIANCE...
Page 50: ...50 CE CERTIFICATE...
Page 51: ...51 CE CERTIFICATE...
Page 52: ...52 CE CERTIFICATE...
Page 53: ...53 CE CERTIFICATE...
Page 55: ...COMMISSIONING SHEET 55...
Page 56: ...SERVICE RECORD 56...
Page 62: ...62...
Page 63: ...63...
Page 64: ...15 10 05 RJ VR2632 VRM3237 UK U287 3089X02 00 060 00012 31437 3...