UK INSTALLATION INSTRUCTIONS
Water Connection
For all closed systems (with flow and return or tank) the system must incorporate an unvented kit with
the components shown below. The safety relieve valve must discharge safely into a suitable drain via a
tundish.
Gas Connection
Refer to BS6891 (Natural Gas) and BS5482 (Propane) for guidance on correct pipe sizing calculation.
There must be 20 mbar Natural Gas (G20) or 34.5 mbar Propane (G31) at the inlet of the appliance with
all appliances at high fire.
Electrical Connection
The heater electrical supply must be installed to the latest I.E.E. regulations. If the unit is hard wired
(moulded plug removed) it must be provided with a fused (5A) local isolator with a contact separation of
3mm minimum on all poles for servicing. Observe polarity and ensure that wiring is correctly restrained.
Isolation
Valve
Y- Strainer Pressure
Reducing
Valve with
Gauge
Double
Check
Valve
Expansion
Vessel
Safety
Relief
Valve
Tundish
Mains
Direct Flow
This information is intended as a guide only, it does not imply
compliance with water or gas installation regulations.
Components will vary depending on the actual installation.
Check local regulations before installation.
Direct feed to the hot water outlets.
Mains is fed directly into the unit. Use a strainer, but a check valve
is not required.
Standard domestic or small commercial set up.
Used with controllers to alter the temperature at the point of use
(only using hot tap) or temperature set on the dip switches for the
maximum needed at any outlet, and mixed down by TMVs or
manual tempering valves.
Draining Point
Cold Supply
Gas
Hot Out
Hot Outlets
25
Summary of Contents for REU-VR2632FFUD - 26i
Page 20: ...20 OPERATION HD50e 26i HD50i...
Page 21: ...21 OPERATION HD70i AC 230V AC 230V HD70e...
Page 38: ...38 DIMENSIONS HD70e...
Page 39: ...39 DIMENSIONS HD70i...
Page 40: ...40 DIMENSIONS HD50e...
Page 41: ...41 DIMENSIONS 26i HD50i...
Page 44: ...44 FLOW CHART 26i HD50e HD50i HD70e HD70i...
Page 45: ...45 WIRING DIAGRAM HD70e HD70i...
Page 46: ...46 WIRING DIAGRAM 26i HD50e HD50i...
Page 47: ...47 DIAGNOSTIC POINTS HD70e HD70i 26i HD50e HD50i...
Page 48: ...48 WATER FLOW CHARACTERISTICS 26i HD50e HD50i HD70e HD70i...
Page 49: ...49 LETTER OF COMPLIANCE...
Page 50: ...50 CE CERTIFICATE...
Page 51: ...51 CE CERTIFICATE...
Page 52: ...52 CE CERTIFICATE...
Page 53: ...53 CE CERTIFICATE...
Page 55: ...COMMISSIONING SHEET 55...
Page 56: ...SERVICE RECORD 56...
Page 62: ...62...
Page 63: ...63...
Page 64: ...15 10 05 RJ VR2632 VRM3237 UK U287 3089X02 00 060 00012 31437 3...