![Rinnai RES-ED4100H-W Instruction Manual Download Page 5](http://html1.mh-extra.com/html/rinnai/res-ed4100h-w/res-ed4100h-w_instruction-manual_1463101005.webp)
RES-ED440H-W
RES-ED450H-W
RES-ED480H-W
40L
0.70
50L
1.05
80L
1.4
100L
1.6
220V
0.7 mPa
30 ~ 80 C (Selectable)
°
°
500W, 1000W, 1500W (Selectable)
220V ~ 10A
> 90 %
Hermetical type water storage style
Horizontal
Model
Rated capacity
Rated voltage
Rated pressure
Rated temperature
Rated power
Water proof degree
Socket
Heating effeciency
Structure type
Installation method
Heat Loss in
(kWh)
24 Hours
IPX4
Specification
6
l
The water inlet and outlet pipe should not be connected in reverse.
l
The wall where electric water heater hang on should be firm, and can hold
two times as the weight of the electric water heater fully filled with water.
Security caution:
l
In order to prevent accident, only use the accessories our company offer and
couldn't changed or replace without any notice.
l
If the accessory is damaged, should be notify our after sales service
department to maintain and replace with the accessories our company offer.
l
If don't comply to above items and cause some accident, our company won't
hold any responsibilities to the direct loss or indirect caused by that.
l
The power plug must be properly grounded and it is prohibited to use the tap
water pipe line as grounding. In the power plug, the nul line shall not be
connected the ground wire. To prevent electric shock, the ground wire shall
not be electrified.
Installation Notice
RES-ED440H-W
RES-ED450H-W
RES-ED480H-W RES-ED4100H-W
MODEL
A
B
C
D
E
F
G
H
380
380
801
685
238
238
316
200
392
392
202
202
G ½”
G ½”
100
100
100
100
430
958
263
420
442
227
G ½”
430
1118
263
580
442
227
G ½”
Dimension
Dimension
Machine body
Connection
mouth for pipe
Hot water outlet
Cold water inlet
Power source wire
with electricity
leakage protection
RES-ED4100H-W
Diagram 5
Mono-directional
security valve
Water inlet valve
Shower
Tap water pipe
Mixed water
valve
Pressure-relief pipe
Hand-rinsing basin
E
F
G
B
C
D
A
H