Rinnai Tankless Water Heater Installation and Operation Manual
5.4.1 Available Temperatures with an Internal Controller
The water heater can deliver water at only one temperature setting at a time. The available temperatures
are provided below. A temperature lower than 120°F (49°C) can be obtained at the tap by mixing with cold
water.
To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the “On/Off”
button on the controller for 5 seconds while the water heater is OFF.
* These models have a default maximum temperature of 120°F (49°C) and an option to increase the maximum
temperature to 140°F (60°C). Refer to section “4.10.1 Parameter settings” for further details.
Do not use the MCC-601 controller with these models.
5.5 Performance Data
To obtain performance data:
1. Press and hold the
(Down) button.
2.
While holding the
(Down) button for 2 seconds, press and hold the
“On/Off” button (hold both buttons simultaneously).
3.
Use the
(Up) and
(Down) buttons to scroll to the desired
information described in Table 22: Performance Data Table.
4. To exit performance data, repeat step 2 above.
5. When complete, the set temperature appears in the display.
Temperature Settings
REP199i/e
REP160i/e
°F
120
125*
130*
135*
140*
°C
49
52
54
57
60
Table 21