21
Ultima II Installation Manual
CONSOLE INSTALLATION, CAVITY TWIN SKIN FLUE
8. FIT RECTANGULAR TO ROUND ADAPTOR
•
Fit adaptor to top of twin skin.
•
Fit 100 mm flue and approved cowl.
•
Flue termination above the roof must comply with
AS/NZS 5601.
•
Locate the longer end inside the aluminium liner of
twin skin.
•
Position elbow into housing.
•
The flue must be supported independently of the
heater to comply with AS/NZS 5601.
•
Attach loosely to housing with screw provided.
•
Measure distance from floor to flue outlet.
•
Adjust elbow to these dimensions, tighten screw.
•
Fit right and left hand rear covers to Heater.
•
Place top spacer (cover) in position temporarily for
wall marking.
•
Remove front cover and inlet union.
9. GAS INLET UNION
•
For ease of connection a combined gas inlet union/
copper elbow is provided with every heater. It is
situated at the bottom right hand side below the
control.
10. REMOVE GAS INLET UNION FROM HEATER
•
The inlet union/elbow should be fitted to the end of
the copper supply tube fore installing the heater in
the fireplace opening.
For access to union:
•
Remove bottom louvre panel, 2 screws in the lower
right and left hand corners of louvres.
•
Remove upper front panel, 2 screws at the bottom
right and left hand edges of the panel.
•
Lift panel to disengage top and remove from heater.
•
Do not lift the panel by the dress guard or top
louvres.
•
Remove union.
•
Ensure that removal and replacement of the bottom
panel is not obstructed by carpet etc.
11. GAS CONNECTION POSITION
•
Drawing is viewed from rear of heater.
•
Actual connection is on right hand side when
viewed from front.
•
Dimensions are to the centre of the flare fitting on
the inlet elbow/union. Flare fitting suits 15 mm
copper tube.