Rinnai RB-27f Instruction Manual Download Page 9

1. Use only certified rubber piping. Ordinary piping is strictly forbidden (no resilience

and not heat proof).

2. Check rubber piping regularly. If signs of ageing, fracture, or slackness are found,

please replace immediately.

Certified

Fractured

3. Please check flame during use at all times.
4. Use soap water to check for gas leakage.
5. After use or before going to bed, check gas

and gas tank are properly turned

off.

6. In case of gas leakage, stop using immediately, turn off gas, and open windows to

allow air circulation. Contact our service center instantly.

7. If gas leakage occurs, do not turn on ventilation system or other electrical

appliances.

built in hob

8. In case of gas poisoning, turn off gas immediately and open windows. Allow patient

plenty of fresh air and send to hospital for treatment.

d. Gas leak prevention and countermeasures

Summary of Contents for RB-27f

Page 1: ...lation e Installation site a Ignition operation b Flame out operation c Governor function a Special notes b Ventilation notes c Fire prevention d Gas leak prevention and countermeasures For domestic u...

Page 2: ...when used with high gas pressure Gas type Description Tanked LP gas Standard gas pressure 1 Glass top plate series Illustration for reference only The actual item may vary 1 Top plate 2 Switch knob 3...

Page 3: ...2 Stainless steel top plate series 5 8 4 6 7 2 3 2 4 6 1 5 7 5 7 4 6 1 3 2 3 1...

Page 4: ...istance to high heat 8 Quick ignition quick ignition device installed to shorten ignition time 4 Installation notes In case installation site consists of flammable materials such as wood or plastic 1...

Page 5: ...m 7 4 Place burner ring cover burner support switch knob accordingly into correct position 5 Battery install from bottom of main body Battery must be installed correctly to enable ignition discharge b...

Page 6: ...sten with fixing ring 5 Leakage test apply neutral detergent soap water onto connector turn on the gas If bubbles appear it means there is leakage Testing with tinder is strictly forbidden 6 Do not sh...

Page 7: ...onding flame level you need b Flame out operation 2 After use remember to cut off the gas to prevent gas leakage and fire breakouts To put out the flame turn knob clockwise back to position as shown i...

Page 8: ...5 Diameter of cookware must not exceed 28 cm weight of cookware must not exceed 15kg or failures may occur 6 Do not bash surface of gas stove This may cause top plate to deform and fracture b Ventila...

Page 9: ...s leakage 5 After use or before going to bed check gas and gas tank are properly turned off 6 In case of gas leakage stop using immediately turn off gas and open windows to allow air circulation Conta...

Page 10: ...neutral detergent then wipe with dry cloth Burner head maintenance If fire vent is blocked by oil residue or flames are abnormal scrub burner head with copper brush and rinse with water Thenwipe dry...

Page 11: ...incorrectly Ignition operation incorrect Air regulation incorrect Switch knob stuck Ignition high tension cable not connected Incorrect gas type Inappropriate ignition operation Ignition device failur...

Reviews: