5. Operation method
A. Ignition operation
Make sure switch knob is turned upwards (as shown in diagram).
1.
Press knob down, do not let go, turn anti-clockwise to ignition position (as
shown in diagram). When flames appear, let go of knob.
2.
3. If flames fail to ignite, try pressing longer on knob.
4. Upon using for the first time, or if built in hob has not been used for a long time,
ignition may take longer because piping is filled with air.
5. Rotate knob to the corresponding flame level you need.
b. Flame out operation
2. After use, remember to cut off the gas to prevent gas leakage and fire breakouts.
To put out the flame, turn knob clockwise back to “
” position (as shown in
diagram).Flames will go out immediately.
●
1.
c. Governor function
1. Blue flames: normal.
Red flames: insufficient air.
Lift fire: Too much air.
2. To mend the problem of red flames or lift fire, adjust
governor inside .
Notes: There are three types of governors available:
1.Type 1 (adjustable)
2.Type 2 (fixed)
3.No governor type.
Sufficient air
Insufficient air
Too much air
(Blue flames)
(Red flames)
(Lift fire)
Less air
More air
Type 1
Adjustment direction
Type 1
Type 2