DIMENSIONS 

 

inch / mm 

Height 

26.8 / 680 

Width 

39.4 / 1000 

Depth 

15.2 / 385 

Left side / vent 

19.5 / 495 

Center to center / vent and 
air supply 

4.7 / 120 

Back / vent 

10.6 / 270 

Left side / gas pipe 

2.6 / 65 

Left side / supply pipe 

7.3 / 185 

Left side / return pipe 

17.5 / 445 

Left side / condensate pipe 

20.9 / 530 

Pipe length of g 

0.7 / 18 

Pipe length of c 

2 / 50 

Pipe length of e, f, k, r, and w 

2.3 / 60 

Back / center of pipe c 

1 / 25 

Back / Center of pipe g 

1.6 / 40 

Back, / center of pipe e, f, k, 
r, and w 

2 / 50 

Pipe length vent co-axial 
Pipe length vent parallel 

2.6 / 65 

5.8 / 147 

Left side / expansion pipe 

23.2 / 590 

Left side / cold water pipe 

34.8 / 885 

Left side / hot water pipe 

37.6 / 955 

 

Top 

2 / 50 

10 / 250 

Back 0 

Front 

6 / 150 

24 / 600 

Left side 

2 / 50 

2 / 50 

Right 
side 

2 / 50 

2 / 50 

Floor / 
Ground 

12 / 300 

30 / 762 

Vent 0  0 

inch / mm  

 

Minimum required 

clearance to 

combustibles and 

non-combustibles 

Recom-

mended 

service 

clearances  

inch / mm  

Clearances 

2.0”

50mm

2.1”

54mm

[5.6”

142mm

10.2”

260mm

12”

305mm

15”

381mm

4.7”

120mm

5.2”

133mm

17.2”

438mm

19.7”

501mm

18.6”

474mm