Rinnai ODHRAD3ML Operation And Installation Manual Download Page 5

Rinnai New Zealand

Manual Outdoor Super Ray Operation and Installation: 

10020-D 04-09

5

Definition of an Outdoor Area

This appliance shall only be used in an above ground open air situation with natural ventilation,  

without stagnant areas and where gas leakage and products of combustion are rapidly 

dispersed by wind and natural convection.

Any enclosure in which the appliance is used shall comply with one of the following:

With walls on all sides, but at least one permanent opening at ground level and no 

overhead cover 

open both 

ends

a)

b)

With a partial enclosure that includes an overhead cover and no more than 2 walls 

Within a partial enclosure that includes an overhead cover and more than 2 walls, the 

following shall apply: 

 

a)  at least 25% of the total wall area is completely open 

b)  at least 30% of the remaining wall area is open and unrestricted 

In the case of balconies, at least 20% of the total wall area shall be and remain open and 

unrestricted

Summary of Contents for ODHRAD3ML

Page 1: ...Domestic Use outdoor only Commercial Use outdoor and indoors subject to room size Not recommended for locations directly near the sea or areas continually subjected to strong winds Appliance must be...

Page 2: ...ring defects only This warranty will not apply if for example the product has been improperly installed or is otherwise installed contrary to manufacturer s recommendations has been damaged during or...

Page 3: ...mage personal injury or loss of life For assistance or additional information contact Rinnai on 0800 RINNAI 0800 746 624 Customer Information Limited Warranty 2 Appliance Location Important 4 Definiti...

Page 4: ...ea on following page Outdoor use only for domestic applications The diagram below shows the required minimum clearances for the appliance to walls floor and ceiling or loose materials such as umbrella...

Page 5: ...s used shall comply with one of the following With walls on all sides but at least one permanent opening at ground level and no overhead cover open both ends a b With a partial enclosure that includes...

Page 6: ...n 1 for a service centre in your area For reliable operation Rinnai Super Rays should be serviced every 2 years If they are in a harsh outdoor environment or intensively used for example in a commerci...

Page 7: ...ord down slowly until a click is heard and check for ignition while holding the cord down Should the heater fail to ignite release the cord and repeat step above After ignition continue to hold down t...

Page 8: ...Rinnai New Zealand Manual Outdoor Super Ray Operation and Installation 10020 D 04 09 Installation Information...

Page 9: ...24 MJ h Gas Type NG and LPG Propane Ignition Piezo ignitor Regulator inbuilt Weight 10 kg Before installation Unpack the appliance and components and check for damage DO NOT install any damaged items...

Page 10: ...ynabolt or equivalent For wood timber number 12 screws or equivalent Hang the heater on the bracket and secure with safety screws Remove lower surround panel and prepare to connect the gas A manual is...

Page 11: ...__________________________________ Address ____________________________________________________________________ ___________________________________________________________________________ Phone ______...

Page 12: ...12 Consumers 0800 RINNAI 746 624 Installers 0800 TO RINNAI 86 746 624 Address 105 Pavilion Drive Airport Oaks Mangere Manukau PO Box 53177 Auckland Airport Manukau 2150 Phone 09 257 3800 Fax 09 257 38...

Reviews: