Rinnai ODHRAD3ML Operation And Installation Manual Download Page 1

Rinnai New Zealand

Manual Outdoor Super Ray Operation and Installation: 

10020-D 04-09

1

MANUAL OUTDOOR SUPER 

RAY NG and LPG

Operation and Installation Manual

Model Numbers

ODHRAD3MN

ODHRAD3ML

Suitable for:

 

Domestic Use   

outdoor only

Commercial Use 

outdoor and indoors (subject to room size)

Not recommended for locations directly near the sea or areas 

continually subjected to strong winds.

Appliance must be installed, commissioned and serviced by a licensed 

tradesperson in accordance with these instructions and all applicable local rules 

and regulations.

Installer, please leave this manual with the customer.

Summary of Contents for ODHRAD3ML

Page 1: ...Domestic Use outdoor only Commercial Use outdoor and indoors subject to room size Not recommended for locations directly near the sea or areas continually subjected to strong winds Appliance must be...

Page 2: ...ring defects only This warranty will not apply if for example the product has been improperly installed or is otherwise installed contrary to manufacturer s recommendations has been damaged during or...

Page 3: ...mage personal injury or loss of life For assistance or additional information contact Rinnai on 0800 RINNAI 0800 746 624 Customer Information Limited Warranty 2 Appliance Location Important 4 Definiti...

Page 4: ...ea on following page Outdoor use only for domestic applications The diagram below shows the required minimum clearances for the appliance to walls floor and ceiling or loose materials such as umbrella...

Page 5: ...s used shall comply with one of the following With walls on all sides but at least one permanent opening at ground level and no overhead cover open both ends a b With a partial enclosure that includes...

Page 6: ...n 1 for a service centre in your area For reliable operation Rinnai Super Rays should be serviced every 2 years If they are in a harsh outdoor environment or intensively used for example in a commerci...

Page 7: ...ord down slowly until a click is heard and check for ignition while holding the cord down Should the heater fail to ignite release the cord and repeat step above After ignition continue to hold down t...

Page 8: ...Rinnai New Zealand Manual Outdoor Super Ray Operation and Installation 10020 D 04 09 Installation Information...

Page 9: ...24 MJ h Gas Type NG and LPG Propane Ignition Piezo ignitor Regulator inbuilt Weight 10 kg Before installation Unpack the appliance and components and check for damage DO NOT install any damaged items...

Page 10: ...ynabolt or equivalent For wood timber number 12 screws or equivalent Hang the heater on the bracket and secure with safety screws Remove lower surround panel and prepare to connect the gas A manual is...

Page 11: ...__________________________________ Address ____________________________________________________________________ ___________________________________________________________________________ Phone ______...

Page 12: ...12 Consumers 0800 RINNAI 746 624 Installers 0800 TO RINNAI 86 746 624 Address 105 Pavilion Drive Airport Oaks Mangere Manukau PO Box 53177 Auckland Airport Manukau 2150 Phone 09 257 3800 Fax 09 257 38...

Reviews: