15
TEMPERATURE CONTROLS
Using 2 or more universal Temperature Controllers.
Switching the system ON.
The hot water system and all controllers can be switched ON and OFF from
any controller by pressing the
ON/OFF
button as shown. When the system
is turned ON the water temperature display will be lit.
During normal operation the system is left ON. Do not push the
ON/OFF
button when water is running.
Using hot water.
Ensure the system is switched
On
by verifying the temperature display is lit.
Ensure the local controller has priority by verifying the
Transfer
LED
indicator is lit. If it is not then press the
Transfer
button once. This gives the
local controller priority of temperature over the system.
Select the desired temperature using the
Hot water temp.
buttons. The
selected temperature will be displayed on all controller displays. This is the
water temperature which will be supplied from the heater.
Bathroom temperatures should be no
more than 50°C.
Open the hot water tap. The appliance will
be activated and the
In Use
indicator will
be lit.
Using 4 Universal Temperature Controllers.
You will need to activate the fourth controller.
STEP 1:
On the Master controller press and hold the
Transfer
and
ON/OFF
buttons simultaneously (see Fig. 2) until a “beep” is heard
(approx. 5 seconds).
STEP 2:
Check that the display on all Four controllers is lit and
displaying a temperature when switched on. If any ONE of the
controllers displays two dashes (see Fig. 1) in the display repeat
STEP 1.
If the master controller is replaced, repeat STEP 1
above for the new controller.
NOTE
Fig. 1
Fig. 2
Summary of Contents for INFINITY 26i
Page 3: ...3 This manual is intended for use by Gas Safe Registered Engineers November 2012...
Page 4: ...4 CONTENTS 3 CONTENTS...
Page 5: ...5 Glossary of Terms and Symbols...
Page 8: ...8 WATER FLOW CHARACTERISTICS 26i HD50e HD50i HD70e HD70i...
Page 9: ...9 DIMENSIONS 26i HD50i...
Page 10: ...10 DIMENSIONS HD50e...
Page 18: ...18 OPERATION HD50e 26i HD50i...