42
TECHNICAL DETAILS
* Minimum operation flow based on temperature setpoint and inlet conditions.
Infinity Model
Infinity 16i
Units
Installation Internal
G20 Nat Gas Press Low
1.8
mbar
G20 Nat Gas Press High
9.0
mbar
G25 Nat Gas Press Low
1.8
mbar
G25 Nat Gas Press High
9.0
mbar
G30 LPG (Butane) Press Low
2.2
mbar
G30 LPG (Butane) Press High
11.4
mbar
G31 LPG (Propane) Press Low
2.2
mbar
G31 LPG Propane) Press High
14.2
mbar
Height 675
mm
Width 370
mm
Depth 130
mm
Weight 15
kg
Flue System
Concentric Forced Draught
Temp. Range Controllers
35 - 60
deg C
Max Temp. via dip switch
75
deg C
Ignition
Direct Electronic Ignition
Gas Consumption Low (Gross)
G20 Nat Gas
4.7
kW
0.4
G25 Nat Gas
4.0
kW
0.4
G30 LPG (Butane)
4.9
kW
.35
G31 LPG (Propane)
4.9
kW
.35
Gas Consumption High (Gross)
G20 Nat Gas
34.9
kW
3.26
G25 Nat Gas
29.6
kW
3.26
G30 LPG (Butane)
36.8
kW
2.6
G31 LPG (Propane)
36.5
kW
2.6
Max Flow raised 25C
15.2
L/min
Min Operation Flow
2.4*
L/min
Water Pressure Nom.
1.1 - 7.0
bar
Power Supply
Electric Consumption
68
Watts
230 V / 50 Hz
m
3
/hr
m
3
/hr
kg/hr
kg/hr
m
3
/hr
m
3
/hr
kg/hr
kg/hr
Summary of Contents for Infinity 16 i
Page 2: ...2...
Page 8: ......
Page 13: ......
Page 21: ......
Page 35: ......
Page 36: ......
Page 37: ......
Page 39: ......
Page 41: ...41 DIMENSIONS...
Page 43: ...43 FLOW CHART...
Page 44: ...44 WIRING DIAGRAM...
Page 46: ...46 LETTER OF COMPLIANCE...
Page 47: ...47 CE CERTIFICATE...