Servicing  

ANNUAL SERVICE 

See Page 25 

 
 

Isolate gas supply and electric supply 

 

Remove Front Panel by means of 4 corner screws 

 

Remove all screws around outer edge of manifold (11) and remove 

 

Inspect and clean injectors on inside of manifold (B). If  heavily contami-
nated remove front cover plate (A) and clean from inside out 

 

        

DO NOT RE-DRILL or ENLARGE ORIFICE 

 

Remove Ignition lead and Ionisation lead 

 

UNLESS GASKET (F)* IS AVAILABLE DO NOT REMOVE SCREWS (E) 

 

Remove remaining screws holding Combustion Chamber  Front Cover (10) 
and Remove Cover Plate 

 

Inspect and clean Ignition (C) and Ionisation Electrodes (D), Inspect for 
cracks. 

 

Remove 2 screws (12) on ledge of main burner box and remove complete 
burner 

 

Clean burners (G) with air brush and  paint brush 

 

Should any burner require individual attention undo screws (H) and remove 
retaining bracket (I) 

 

Inspect Combustion Chamber and base of Heat Exchanger. Check for signs 
of damage / leaking 

 

Disconnect fan wiring (J) 

 

Remove  3 x Fan retaining screws (13) and remove fan from unit 

 

Inspect fan Impellor and clean as require 

 

Re Build in Reverse Order 

Summary of Contents for Infinity 11e

Page 1: ...Service Manual Continuous Flow Water Heater Important Read these instructions carefully before attempting installation or use of this appliance All work must be carried out by competent persons...

Page 2: ...2 c...

Page 3: ...3 June 2010 Issue 1 This manual is intended for use by Gas Safe Regisetred Engineers...

Page 4: ...nd Pressures 9 4 Dimensions 10 5 Remote Controls 11 6 Cutaway Diagram 14 7 Operational Flow Chart 16 8 Main Components 17 9 Wiring Diagram 19 10 Dip Switch Setting 20 11 Error Codes 21 12 Diagnostic P...

Page 5: ...5 Glossary of Terms and Symbols...

Page 6: ...6 Introduction...

Page 7: ...7 Specification...

Page 8: ...8 Specification...

Page 9: ...9 Water Flow Rates and Pressures...

Page 10: ...10 Dimensions...

Page 11: ...11 Remote Controls...

Page 12: ...e over the system Select the desired temperature using the Hot water temp buttons The selected temperature will be displayed on all controller displays This is the water temperature which will be supp...

Page 13: ...use there may be a variation between the temperature displayed at the controller and the temperature at the tap Do not clean the control with solvents or detergents Use only a soft damp cloth TEMPERAT...

Page 14: ...14 Cutaway Diagram...

Page 15: ...15 Cutaway Diagram...

Page 16: ...16 Operational Flow Chart...

Page 17: ...17 Main Components...

Page 18: ...18 Main Components...

Page 19: ...19 Wiring Diagrams...

Page 20: ...20 Dip Switch Settings...

Page 21: ...21 Error Codes...

Page 22: ...22 Diagnostic Points...

Page 23: ...23 Gas Pressure Setting...

Page 24: ...24 Gas Pressure Settings...

Page 25: ...25 Servicing Burner...

Page 26: ...MOVE SCREWS E Remove remaining screws holding Combustion Chamber Front Cover 10 and Remove Cover Plate Inspect and clean Ignition C and Ionisation Electrodes D Inspect for cracks Remove 2 screws 12 on...

Page 27: ...ible Check burner pressure as per page 23 Once burner pressures have been checked and correct turn off water outlets Isolate Gas supply and remove manometer Reseal Test Nipple Reinstate gas supply Ope...

Page 28: ...28 Spares...

Page 29: ...29 Spares...

Page 30: ...30 Spares...

Page 31: ...31 Spares...

Page 32: ...32 Spares...

Page 33: ...33 Spares...

Page 34: ...34 Spares...

Page 35: ...35 U K Warranty...

Page 36: ...36 U K Contact Ver 1 19 10 21 RUK Tech Dept Ian Jenkins...

Reviews: