background image

Rinnai 16 

HOTFLO (HFE Series) Electric Storage Water Heater OIM

This appliance 

MUSTBE

 installed by a qualified person in accordance with: 

• 

Manufacturers installation instructions 

• 

Current AS/NZS 3000 wiring rules 

• 

Current AS/NZS 3500�4 Plumbing and drainage 

• 

All local regulatory requirements 

This appliance is 

NOT

suitable for use as a spa or swimming pool heater�

LOCATION

The Rinnai Hotflo (HFE Series) storage water heater range have an ingress protection rating of IPX4 making them 

suitable for internal or external installation�
The water heater should be placed as close as practicable to the most frequently used hot water outlet point or 

points to minimize the delay time for hot water delivery� This will usually be the kitchen tap� For installations where 

the distance between the water heater and the outlets is considerable, a flow and return system can be used which 

will minimize the waiting time for hot water delivery� 

It is recommended that the water heater is installed at ground or floor level. It 

MUSTBE

 installed in a vertically 

upright position� The water heater 

MUSTBE

 accessible without the use of a ladder or scaffold� Installation into roof 

spaces 

MUST

 comply with local regulatory authority requirements�

Ensure the PTR valve, isolating valves, access covers, thermostats and heating elements have sufficient clearances 

and are accessible for service and removal� The information on the rating plates 

MUST

 also be readable�

The water heater 

MUST BE

 installed in free standing mode on a level and stable base in a manner that is 

acceptable to local authorities� Avoid situations that may result in pooling of water around the base of the water 

heater�
Where property damage can occur as a result of water leakage, the water heater 

MUSTBE

 installed with a safe 

tray (overflow tray) and drain. Construction, installation and draining of the safe tray 

MUST

 comply with local 

regulatory requirements and� AS/NZS 3500�4 also requires the use of a safe tray for particular situations�

WATER QUALITY

The water quality of most public supplies is suitable for the water heater� Water quality from bore wells is generally 

unsuitable� Refer to the ‘Warranty Conditions’ for water quality parameters and how they affect warranty� If in doubt 

about water quality, have it checked against the parameters listed in the warranty conditions� 

If sludge or foreign matter is present in the water supply, a suitable strainer or filter should be incorporated in the 

water supply to the water heater� 

Scaling water is defined as having a total hardness in excess of 200 mg/litre (expressed as calcium carbonate) or 

a Saturation Index in excess of +0�4� Areas that have a scaling water supply include South Australia and Western 

Australia� In a scaling water supply, calcium carbonate and possibly other compounds are deposited out of the 

water onto any hot metallic surfaces and form a scale�
In areas of scaling water an ECV 

MUSTBE

 fitted on the cold water line between the non‑return valve and the 

connection to the water heater to protect the PTR valve and the water heater� Local regulatory authorities may 

require that an ECV be fitted. The ECV is to be supplied and fitted by the installer.

MAINS PRESSURE

The Rinnai Hotflo (HFE Series) electric storage water heater range utilise mains pressure by connecting directly to 

the mains water supply� If the mains water supply pressure in your area exceeds the rated pressure of the water 

heater a PLV 

MUSTBE

 fitted.

The mains water supply pressure should be greater than 350kPa for true mains pressure operational performance 

to be achieved�

INSTALLATION

Summary of Contents for HOTFLO HFE125S18

Page 1: ...egulation All local regulatory requirements including all local OH S requirements This appliance must be installed maintained and removed by a Qualified Person For continued safety of this appliance i...

Page 2: ...Rinnai 2 HOTFLO HFE Series Electric Storage Water Heater OIM This page is intentionally blank...

Page 3: ...ns 12 Installation Methods 13 Hot Water Plumbing System Example No Temperature Limiting Device 13 Hot Water Plumbing System Example With Temperature Limiting Device 13 Hot water plumbing system Exampl...

Page 4: ...Rinnai 4 HOTFLO HFE Series Electric Storage Water Heater OIM This page is intentionally blank...

Page 5: ...rules and regulations For continued safety of this appliance it must be installed operated and maintained in accordance with the manufacturer s instructions This appliance is heavy use 2 people or mec...

Page 6: ...trades person WARNING The thermostat setting must only be adjusted by an Electrician or other suitably qualified trades person The access cover to the element and thermostat must only be removed by an...

Page 7: ...by a qualified person It is normal for the PTR valve to release a small quantity of water through the drain pipe during heating If the valve dribbles or leaks continuously try easing the valve gear fo...

Page 8: ...eated during the set period and stored The Off Peak supply is usually cheaper Electricity supply types and tariffs vary according to the local electricity authority Twin Element Model A vitreous ename...

Page 9: ...may need to be increased Contact your installer or Rinnai to discuss adjusting the thermostat No water from the hot tap Restriction in the hot tap or failure of the cold water supply to the heater Che...

Page 10: ...D WARNING LABELS LEFT COLD WATER INLET Connection RP 3 4 20mm LEFT HOT WATER OUTLET Connection RP 3 4 20mm use a union connection and Insulate Hot water pipe PTR VALVE DRAIN PIPE Supplied by Installer...

Page 11: ...y F Electrical Entry Upper Element G HFE25S 452 490 415 297 153 80 HFE50S 694 490 415 524 158 80 HFE80S 900 590 515 683 225 155 HFE125S 1245 590 515 1020 225 155 HFE160S 1530 590 515 1310 225 155 HFE2...

Page 12: ...4 HFE160T36 HFE160T48 160 1800 2400 3600 4800 1800 2400 3600 4800 HFE200S24 HFE200S36 HFE200S48 200 2400 3600 4800 HFE250SSL36 HFE250SSL48 250 3600 4800 HFE250T36 HFE250T48 250 3600 4800 3600 4800 HFE...

Page 13: ...E LIMITING DEVICE KITCHEN LAUNDRY ENSUITE BATHROOM TEMPERED Supply NON TEMPERED SUPPLY NON RETURN VALVE TEMPERATURE LIMITING DEVICE TLD NON RETURN VALVE NON RETURN VALVE PLV 500 kPa Not Supplied with...

Page 14: ...t Supplied with all models ECV Not Supplied 700 kPa or 850 kPa ISOLATING VALVE PTR VALVE Supplied 850 kPa or 1000 kPa WATER HEATER COLD Supply ISOLATING VALVE NON RETURN VALVE FLOW RETURN PUMP ISOLATI...

Page 15: ...0 kPa WATER HEATER COLD Supply NON RETURN VALVE FLOW RETURN PUMP ISOLATING VALVE UNTEMPERED SUPPLY TLD CAUTION Valves with pressure ratings other than specified are unsuitable and MUST NOT be used For...

Page 16: ...n occur as a result of water leakage the water heater MUST BE installed with a safe tray overflow tray and drain Construction installation and draining of the safe tray MUST comply with local regulato...

Page 17: ...s under Installation Methods WARNING Valves with pressure ratings other than specified MUST NOT be used An isolation valve and non return valve MUST BE fitted in the cold water supply to the water hea...

Page 18: ...BE fitted to the valve outlet in accordance with the section Relief Valve Drain Lines on the bottom of page 18 The valve body MUST BE insulated in accordance with local regulatory requirements and AS...

Page 19: ...g element Check the available tariffs with the local electricity supplier The Off Peak overnight is usually the most economical for the customer Electrical Connections WARNING The water heater MUST BE...

Page 20: ...fore removing the access cover to the element and thermostat The access cover to the element and thermostat MUST ONLY BE removed by an Electrician or other suitably qualified trades person The thermos...

Page 21: ...Air will now be forced out of the taps 3 Close each tap when water runs freely without air bubbles 4 Check all plumbing connections and pipe work for water leaks 5 Connect the water heater to the ele...

Page 22: ...ce please call our National Help Line Rinnai recommends that this appliance be serviced every year Head Office 100 Atlantic Drive Keysborough VIC 3173 P O Box 460 Braeside Victoria 3195 Product Sales...

Reviews: