18. Gas Conversion Procedure
q
g
① Turn OFF main gas valve
② Disconnect 240V power supply
③ Remove Front Cover
④ Remove Remote Control
Replacement of Manifold
① Remove Flame Rod Connection terminal
② Pull off high tension lead
③ Remove Manifold assembly
Screws (9)
Manifold - Gas Control (3)
Manifold - Burner (6)
Clean combustion deposits on the burner
if necessary
④ Replace Manifold fit Gasket to Gas
Control.
REU-V2626W For NG: U245-200-B 92092550
For Propane: U245-200-A 92092089
REU-V2632WC For NG: U245-200-C 92094317
For Propane: U245-200-A 92094309