Infinity REU-V2626W / HD200E REU-V2632WC
- 29 -
Issue 1 - 10/10/03 ©Rinnai
3d.Valve Circuit
a.)
Disconnect Solenoid connector (E
4
), measure resistance between Brown and Black.
Normal:
1.7~2.0k
Ω
If normal, proceed to
b
.).
Faulty:
Replace Solenoid Valve 3.
b.)
Measure voltage between Brown and Black of SV
3
connector.
Normal:
DC80~100V
If normal, proceed to Modulating valve
circuit.
Faulty
:
Replace PCB.
c.)
Disconnect Modulating Valve fasten terminal and measure resistance between terminals.
Normal: 6
7~81
Ω
If normal, proceed to
b
.).
Faulty
:
Replace Modulating Valve.
d.)
Measure voltage between Pink and Pink of Modulating Valve fasten terminal.
Normal:
DC2~15V
If normal, proceed to
c
.).
Faulty:
Replace PCB.
e.)
Check the gas secondary pressure change when set temperature on the remote control changes
from 37 to 55
°
C.
Normal:
If secondary pressure changes, go to Water Flow Servo Circuit.
Faulty:
Replace Modulating Valve.
4. Flame Rod Circuit
Check flame rod.
Disconnect flame rod terminal (C
1
), and re-operate.
“72” indicated:- Proceed to 3.
“72” is not indicated:- check for electrical leaks from the flame rod.
Measure resistance between flame rod terminal (C
1
) and appliance earth.
Normal:
>1M
Ω
If normal, replace PCB.
Faulty:
Replace flame rod.
a.) Remove the Flame Rod terminal (C
1
) repeat operation procedure, if 72 is displayed again check
the Hot water outlet thermistor.
If 72 is not displayed check current leakage from the Flame Rod.
b.) Measure voltage between body earth and Flame Rod terminal (C
1
).
Normal:
Voltage AC5~150V
If normal, replaced PCB
Faulty:
Replace Flame Rod.
c.) Check if the Flame Rod is securely fitted.
Normal:
replace the PCB
Faulty:
Adjust the fitting of the Flame Rod
Summary of Contents for HD200E REU-V2632WC
Page 13: ...Infinity REU V2626W HD200E REU V2632WC 8 Issue 1 10 10 03 Rinnai 4 Dimensions...
Page 18: ...Infinity REU V2626W HD200E REU V2632WC 13 Issue 1 10 10 03 Rinnai 6 Cutaway Diagram...
Page 19: ...Infinity REU V2626W HD200E REU V2632WC 14 Issue 1 10 10 03 Rinnai 7 Operational Flow Chart...
Page 25: ...Infinity REU V2626W HD200E REU V2632WC 20 Issue 1 10 10 03 Rinnai 11 Wiring Diagram REU V2626W...
Page 26: ...Infinity REU V2626W HD200E REU V2632WC 21 Issue 1 10 10 03 Rinnai REU V2632WC...
Page 56: ...Infinity REU V2626W HD200E REU V2632WC 51 Issue 1 10 10 03 Rinnai 20 Exploded Diagram...
Page 57: ...Infinity REU V2626W HD200E REU V2632WC 52 Issue 1 10 10 03 Rinnai...
Page 58: ...Infinity REU V2626W HD200E REU V2632WC 53 Issue 1 10 10 03 Rinnai...
Page 59: ...Infinity REU V2626W HD200E REU V2632WC 54 Issue 1 10 10 03 Rinnai...
Page 67: ...Infinity REU V2626W HD200E REU V2632WC Issue 1 10 10 03 Rinnai Notes...
Page 68: ......