Rinnai GHF4135L Operation & Installation Manual Download Page 20

Rinnai Australia

19

OIM 2013/13305 GHF4135N/GHF4170N, Issue 3 - 02/06/16

Head Office

   

100 Atlantic Drive,
Keysborough, Victoria 3173
P.O. Box 460
Braeside, Victoria 3195
Tel:  (03) 9271 6625
Fax: (03) 9271 6622

National Help Line
Tel:  1300 555 545*     Fax: 1300 555 655*

*Cost of a local call higher from mobile or public phones.

Australia Pty. Ltd.  

ABN 74 005 138 769

Internet: www.rinnai.com.au   E-mail: [email protected]

Rinnai has a Service and Spare Parts network with personnel who are fully trained 
and equipped to give the best service on your Rinnai appliance. If your appliance 
requires service, please call our National Help Line. Rinnai recommends that this 
appliance be serviced annually.

Summary of Contents for GHF4135L

Page 1: ...gas products are A G A certified This appliance shall be installed in accordance with Manufacturer s Installation Instructions Current AS NZS 3500 AS NZS 5601 Local Regulations and Municipal Building...

Page 2: ...This page is intentionally blank...

Page 3: ...ating 6 Pressure Temperature Relief Valve 6 Cold Water Connection 7 Insulation of Pipes 7 Temperature Protection 7 Inlet Connections 7 Appliance Dimensions 8 Appliance Specifications 9 Gas Connections...

Page 4: ...mation contact the Victorian Building Authority on 1300 815 127 Heated water can be dangerous especially for young children and the infirm Water temperatures above 50 C can cause severe burns instantl...

Page 5: ...ed for use in areas where the Total Dissolved Solids TDS content of the water supply is less than 2500 mg L In areas where the TDS exceeds 600mg L the magnesium alloy anode supplied in the heater may...

Page 6: ...ried out by your local Rinnai agent The service should include the following Replace the Pressure and Temperature Relief Valve Replace the anodes in areas of harsh or adverse water conditions a more f...

Page 7: ...here the water heater is subjected to wet conditions Minimum clearance around the windows and doors must be maintained refer to AS NZS 5601 In areas where water pipes are prone to freezing drain lines...

Page 8: ...ure This water heater is designed for direct connection to water supply pressures of no greater than 800 kPa On All Models Where the mains pressure can exceed or fluctuate beyond the pressure shown ab...

Page 9: ...scald injury it is mandatory under the requirements of Australian Standard AS NZS 3500 4 that a suitably approved temperature control device be fitted to the hot water supply to outlets used primaril...

Page 10: ...135N L GHF4170N L Storage Capacity L 135 170 Gas Pipe Height mm 276 Cold Water Inlet Height mm 328 403 Hot Water PTR Port Height mm 988 1213 Gas Pipe Depth mm 459 Cold Hot PTR Port Depth mm 210 Overal...

Page 11: ...ulator is fitted with an RC 15 socket A union connection should be used For LPG commissioning the SIT gas controls integrated pressure regulator is bypassed and the gas pressure adjusted via the Maxit...

Page 12: ...depressed for twenty 20 seconds after the pilot flame lights The pilot flame can be observed when on 6 Release the knob and check if the pilot is still alight 7 If pilot has failed to light turn gas c...

Page 13: ...ulator and using a Philips head screw driver rotate the adjusting screw until the TPP described above is achieved 4 Replace SIT Gas Control A and the Seal Cap on the regulator Ignition System Spark Ga...

Page 14: ...hot water usage of showers washing machines and dishwashers can be under estimated Review these appliances to determine if your daily usage is greater than the storage volume of your water heater For...

Page 15: ...ng central shower blocks 2 Water heater s supplying kitchens used for the bulk preparation of food 3 Water heater s used in commercial or industrial heating processes 4 Water heater s used in hydronic...

Page 16: ...tion or repair of the hot water unit other than by an approved Rinnai agent or a Technician of a gas or electricity utility approved by Rinnai c Attachment of any parts or accessories other than those...

Page 17: ...ter utilities where the chemistry is deliberately altered by parties other than the water utility before supplying the water heater 9 This warranty does not apply to damage caused by sludge and or sed...

Page 18: ...clearances combustible clearances windows and surrounds etc 2 Gas pressure checked and set 3 Appliance tested for correct operation and to ensure no gas leaks 4 Is the end user fully aware of operatin...

Page 19: ...This page is intentionally blank...

Page 20: ...1300 555 655 Cost of a local call higher from mobile or public phones Australia Pty Ltd ABN 74 005 138 769 Internet www rinnai com au E mail enquiry rinnai com au Rinnai has a Service and Spare Parts...

Reviews: