TESTING & COMMISSIONING

TESTING PROCEDURE

Turn gas supply on and plug the unit into the power supply. (Caution 240V.)

 

TO CHECK BURNER PRESSURE

   Refer to Data Plate.

   Remove test point screw and attach manometer to test point. 

    The test point is on the front side of the gas valve.
    Light heater, push control buttons to the high position and 
    check pressure.  

   If adjustments are necessary, the regulator is situated on

    the front of the gas control. 

 

   

After checking pressure, turn the unit off, remove manometer and replace test point screw.

•    

Turn the heater on and off a few times to check ignition.

•    

When you are satisfi ed that the heater is working correctly, reassemble panels.

•    

All burner aeration is factory preset and cannot be adjusted.

•    

If you are unable to get the unit to operate correctly, refer to Troubleshooting on Page 5, 

     before contacting your local service agent as listed on Page 10.

•    

It may take approximately 2 hours for the logs to achieve their full fl ame pattern and glow.

    

During the initial burning in period, some smoke and smell may be experienced. The

     heater should be run on the high position in a well ventilated room until these dissipate. 

 

 

INSTRUCT CUSTOMER ON USE OF UNIT

Explain to customer about use and care of unit.  Make sure the customer understands the instructions.

   EXPLAIN

Ignition, Adjusting heat level, Fan Switch, Turning “OFF”.

COMMISSIONING

  

INSTALLATION AND COMMISSIONING CHECKLIST

Complete the installation / commissioning checklist and the installer / gasfi tter details on page 12 and 
make sure that this instruction book is left with the customer.

NOTE: 

RINNAI RESERVES THE RIGHT TO CHANGE OR MODIFY SPECIFICATIONS WITHOUT NOTICE.

Summary of Contents for FS 35

Page 1: ...Service Contacts Installation Checklist Installer Details IMPORTANT This appliance shall be installed in accordance with Manufacturers Installation Instructions Local Gas tting regulations Municipal...

Page 2: ...ond that expected from conditions of normal use 3 Warranty claims may be invalid if not accompanied by details of the installing or supervising gas tter s registration number and the gas tting certi c...

Page 3: ...ll ignite additional burners as shown in the diagram There is no need to hold the buttons for 15 seconds when increasing the heat SETTING INPUT BUTTONS FAN BURNER PATTERN TO DECREASE THE HEAT This is...

Page 4: ...used near the heater when it is in use Young children should be supervised at all times Hand or body contact with the louvres should be avoided Do not allow young children or the in rm to sleep direc...

Page 5: ...cleaning purposes TROUBLESHOOTING SYMPTOM CAUSE SOLUTION Burner will not light No power present Ensure power cord is plugged in and turned on Power cut Re ignite after power is restored Air in gas pi...

Page 6: ...ntact with it In some cases curtains may need restraining See below for minimum clearances required 4 The heater is not designed to be built into bookcases or shelves or any combustible opening 5 Chec...

Page 7: ...This heater requires a minimum 3m ue Position the heater Suspend a plumbline from the ceiling to the centre of the ue socket Mark the centre of the ue in the ceiling Make a small hole in the ceiling...

Page 8: ...ating pins of the Main Log as shown Gently place loose ember bed material in front of the front log Do not pour as dust particles from the plastic bag may block the burner ports Level it with a pencil...

Page 9: ...djusted If you are unable to get the unit to operate correctly refer to Troubleshooting on Page 5 before contacting your local service agent as listed on Page 10 It may take approximately 2 hours for...

Page 10: ...ing 90W Bottom R H side of pillar 10 SERVICE CONTACT POINTS RINNAI AUSTRALIA PTY LTD ACN 005 138 769 Helpline 1300 366 388 Mon Fri 8 30am 5 30pm EST Cost of a local call higher from mobile or public p...

Page 11: ......

Page 12: ...Has the appliance been commissioned 9 Is the end user fully aware of operating procedure NO YES INSTALLER GASFITTER DETAILS Company Name ______________________________________________________________...

Reviews: