Rinnai FS 35 Operating And Installation Instructions Download Page 10

Comple

Model:

 

 

 

 

 

               

Description:

Input: 

 

               

Gas Control: 

                   

Burner:     

                        

Gas Inlet:  

                       

Test Point Pressure:

       

Flue: 

 

 

           

Flue Termination: 

          

 

 

 

           

Ignition:

 

 

           

Power Supply:

            

 

 

 

           

 

 

 

          

Fan: 

 

                     

Data Plate:  

                                 

TECHNICAL DATA

FGL35 FBN (NG) Australia
FGL35 FBL (Propane) Australia
FS35N (NG) New Zealand
FS35L (Propane) New Zealand
Rinnai Inbuilt Radiant/Convector, glass-fronted, ceramic log space heater 
with forced convection and natural draught fl ue system.
35 MJ/h Natural Gas and Propane.
Rinnai Push-Button Combination Control.
Ceramic Logs, Ember Bed and Heat Burner.
15mm. Copper Flare Connection.
Natural Gas 0.95 kPa; Propane 2.60 kPa.
Natural Draught.
An approved 100mm. cowl must be fi tted
to all installations.
Electronic Spark.
230/240v. 50Hz unit is supplied with 3 pin
plug and supply lead, replace only with
Rinnai P/N 90179599(Aust.) 6765B(NZ).
Tangential 2 Speed, Watt Rating 90W.
Bottom R/H side of pillar. 

10

SERVICE CONTACT POINTS

RINNAI AUSTRALIA PTY. LTD. ACN. 005 138 769

Helpline:

 

1300 366 388

Mon.-Fri (8.30am-5.30pm EST)
 (Cost of a local call - higher from mobile or public phones)

Internet: www.rinnai.com.au

   

 

 

Email: [email protected]

VIC./TAS:
Head Offi ce

:

 

10-11 Walker St. Braeside, Vic. 3195

                       

Tel

.(03) 9271 6625 

Fax

.(03) 9271 6622

                  

     Sales

 

Tel

.(03) 9271 6666 

Fax

.(03) 9271 6611

                  

     Service

 

Tel

.(03) 9271 6699 

Fax

.(03)  9271  6688    

NSW./ACT:    

62 Elizabeth St. Wetherill Park, NSW 2164

 

      

    Tel.

 (02) 9609 2888 

Fax.

 (02) 9729 5260

SA./NT: 

         140 Days Rd. Ferryden Park, SA. 5010

 

    

      Tel.

 (08) 8345 0292 

Fax.

 (08) 8345 4760

WA: 

18 Belgravia St. Belmont, WA. 6104

 

Tel.

 (08) 9478 3355 

Fax.

 (08) 9277 2531

QLD:

  1/6 Booran Drive, Logan Central, Qld. 4114

         

   Tel.

 (07) 3209 4622 

Fax.

 (07) 3209 4722

RINNAI NEW ZEALAND LTD.

Internet:

 

www.rinnai.co.nz

 

Email:

 

[email protected]

105 Pavilion Drive, Airport Oaks, Mangere, Auckland, NZ.
PO Box 53177, Auckland Airport, Manukau, 2150  

Tel

. +64 9 257 3800 

Fax

. +64 9 257 3899

24 Hr. Service 

Tel

. 0800 867 46624 (

0800 TORINNAI

)

Summary of Contents for FS 35

Page 1: ...Service Contacts Installation Checklist Installer Details IMPORTANT This appliance shall be installed in accordance with Manufacturers Installation Instructions Local Gas tting regulations Municipal...

Page 2: ...ond that expected from conditions of normal use 3 Warranty claims may be invalid if not accompanied by details of the installing or supervising gas tter s registration number and the gas tting certi c...

Page 3: ...ll ignite additional burners as shown in the diagram There is no need to hold the buttons for 15 seconds when increasing the heat SETTING INPUT BUTTONS FAN BURNER PATTERN TO DECREASE THE HEAT This is...

Page 4: ...used near the heater when it is in use Young children should be supervised at all times Hand or body contact with the louvres should be avoided Do not allow young children or the in rm to sleep direc...

Page 5: ...cleaning purposes TROUBLESHOOTING SYMPTOM CAUSE SOLUTION Burner will not light No power present Ensure power cord is plugged in and turned on Power cut Re ignite after power is restored Air in gas pi...

Page 6: ...ntact with it In some cases curtains may need restraining See below for minimum clearances required 4 The heater is not designed to be built into bookcases or shelves or any combustible opening 5 Chec...

Page 7: ...This heater requires a minimum 3m ue Position the heater Suspend a plumbline from the ceiling to the centre of the ue socket Mark the centre of the ue in the ceiling Make a small hole in the ceiling...

Page 8: ...ating pins of the Main Log as shown Gently place loose ember bed material in front of the front log Do not pour as dust particles from the plastic bag may block the burner ports Level it with a pencil...

Page 9: ...djusted If you are unable to get the unit to operate correctly refer to Troubleshooting on Page 5 before contacting your local service agent as listed on Page 10 It may take approximately 2 hours for...

Page 10: ...ing 90W Bottom R H side of pillar 10 SERVICE CONTACT POINTS RINNAI AUSTRALIA PTY LTD ACN 005 138 769 Helpline 1300 366 388 Mon Fri 8 30am 5 30pm EST Cost of a local call higher from mobile or public p...

Page 11: ......

Page 12: ...Has the appliance been commissioned 9 Is the end user fully aware of operating procedure NO YES INSTALLER GASFITTER DETAILS Company Name ______________________________________________________________...

Reviews: