Rinnai FM10LA Operation & Installation Manual Download Page 1

Gas Instantaneous Water Heater 

Operation & Installation Manual

Models:

FM10NA
FM10LA
 

Summary of Contents for FM10LA

Page 1: ...Gas Instantaneous Water Heater Operation Installation Manual Models FM10NA FM10LA...

Page 2: ...nding of the appliance to ensure safe and correct use This appliance must be installed in accordance with Manufacturer s Installation Instructions Current AS NZS 3500 4 AS NZS 5601 Local Regulations a...

Page 3: ...ory Information 4 Notice to Victorian Consumers 4 Warning About Hot Water 4 Features Benefits 6 Features and Benefits 6 Operation 7 To Operate 7 Delivery Temperature 7 Water Flow and Temperature Adjus...

Page 4: ...must conform to local regulations including local OH S requirements The installation must also comply with the instructions supplied by Rinnai Please keep this instruction booklet in a safe place for...

Page 5: ...instantaneous water heaters referred to in this manual are incompatible with solar water heating systems A dedicated range of solar compatible gas continuous flow water heaters is available from Rinn...

Page 6: ...is very low Unlike most other instantaneous water heaters this model is fitted with a battery powered electronic ignition and microprocessor control module offering unique benefits as follows Electron...

Page 7: ...e at the bottom of the appliance Approximate battery life is 6 to 12 months Actual battery life may be different depending on individual hot water usage patterns 1 Locate the battery compartment and o...

Page 8: ...ing the tap a little as this will reduce the water flow rate The appliance has a minimum water flow rate that is required for operation If the water heater does not activate when opening a tap the flo...

Page 9: ...Low water flow Low water pressure Check water pressure to appliance Blocked outlet fixture Check and clean Other Service call Cuts off when operating Interrupted gas supply Service call Run out of cyl...

Page 10: ...Rinnai 10 HW_GI_FM10 OIM This page is intentionally blank...

Page 11: ...ipe Sizing 12 Water Supply 13 Hot Water Delivery Temperature 13 Appliance Mounting Requirements 13 Appliance Mounting Method 14 Service Connection Points 14 Flueing 15 Appliance Flue Terminal 15 Commi...

Page 12: ...ed for Outdoor Installation only As such it MUST BE located in an above ground open air situation with natural ventilation without stagnant areas where gas leakage and products of combustion are rapid...

Page 13: ...lations and or the requirements of AS NZS 3500 4 must be considered regarding the temperature limitations of hot water supplied to areas used primarily for personal hygiene The temperature of water to...

Page 14: ...heater onto the 3 appliance mounting fixings installed in step 2 Ensuring that all 3 mounting points are securely engaged SERVICE CONNECTION POINTS NOTE See Table 1 Specification table for individual...

Page 15: ...1 500 n Vertically below an openable window non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation For space heaters up to 50 MJ h input 150 For oth...

Page 16: ...er do not light then the gas pressure at the outlet of the regulator is too low Increase the pressure at the outlet of the regulator by slowly turning the adjustment screw clockwise until a suitable p...

Page 17: ...on Record is a reference for the end user help line staff and service technicians Ensuring that this information is available here will be helpful in the event that a service enquiry is required Insta...

Page 18: ...Water Pressure For Operation Maximum Inlet Water Pressure Hot Cold Water Natural Gas Propane Gas FM10 120 40 1000 14 R 1 2 BSP Male R 1 2 BSP Female R 1 2 BSP Male Model Gas Type Inlet Gas Pressure kP...

Page 19: ...igure 4 Dimensions Approximately 175 to base of fittings 61 51 575 170 838 425 48 380 205 201 219 380 120 120 120 120 70 70 70 51 Location of upper rear mounting holes Location of lower rear mounting...

Page 20: ...Voltage Lead Ignition Flame Rod Temperature Overheat Switch Self resetting Modulation Motor Thermistor Heated water outlet temperature Micro switch SV1 SV2 HV FR TTB M NTC SW MAIN MICROPROCESSOR TEMPE...

Page 21: ...Rinnai 21 HW_GI_FM10 OIM NOTES...

Page 22: ...Rinnai 22 HW_GI_FM10 OIM NOTES...

Page 23: ...Rinnai 23 HW_GI_FM10 OIM...

Page 24: ...or public phones For further information visit www rinnai com au or email enquiry rinnai com au Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give t...