40
EX38DT Installation and Operation Manual
Issue
No ON
Indicator
No
Burner
Ignition
Abnormal
Combustion
Loss of
Combustion
Gas
Smell
Noisy
Ignition
Takes too
Long to
Warm
Room
Remedy
Not Plugged in
Plug
in
Power Failure
Restart
Unit
(Initial
Installation) Air
in Gas Pipe
Purge Air
(Installer)
Gas Filter
Blocked
Service Call
Missed Ignition
Service
Call
Flue Terminal
Obstructed
Clear
Obstruction
Flue Manifold
Not Connected
Service
Call
Louver
Obstructed
Clear
Obstruction
Air Filter
Blocked
Clean Filter
Gas Escape
Service
Call
Lock Set
Cancel
Lock
Gas Off at
Meter, Tank, or
Valve
Turn
Gas
On
ON Timer is set
Cancel “ON”
Timer
Additional Troubleshooting Remedies
Table 10: Troubleshooting Remedies