Rinnai Corporation EX08CT, EX11CT Manual
35
If any of the original wire as supplied
with the appliance must be replaced,
it must be replaced with type 18
AWG wire or its equivalent.
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation.
CAUTION
CODE
COLOR
bk
black
bl
blue
gr
green
gr/y
green/yellow
r
red
w
white
y
yellow
gy
gray
or
orange
br
brown
MARK
PART NAME
MARK
PART NAME
MS
MAIN SWITCH
OH.TH
OVER HEAT THERMISTOR
R.TH
THERMISTOR
OHS1, 2
OVER HEAT SWITCH 1, 2
TF
THERMAL FUSE
FM
CONVECTION FAN MOTOR
F
FUSE
SP
SPARKER
ER
ELECTRODE
SV1, 2
MAIN SOLENOID VALVE 1, 2
POV
MODULATING SOLENOID
VALVE
BL
COMBUSTION FAN MOTOR
TR
TRANSFORMER
PS
PRESSURE SENSOR
FR
FLAME ROD
W. TH
WALL THERMOSTAT
Wiring Diagram