Drilling
Flue
Hole
Ensure that there are no gas or water lines, or
electrical circuits in the wall location where the flue
hole is to be drilled.
Drill the flue hole using a 3 1/8 inch (80 mm) drill.
The center of the hole must be located anywhere
within the shaded area, unless extension kits are
used. See diagram.
For weatherboard walls, drill through the center of
the weatherboard from the outside first and then
through the plasterboard. A template is provided.
For installation without using extension kits, the
configuration of the flue manifold, air intake hose,
and exhaust slide pipe should be as shown when
installation is completed. The shaded area shows
where the flue manifold can be located.
Configuration viewed from behind the appliance.
Flue Hole
3 1/
8"
(8
0
mm)
Use a template (included) to
determine allowable location of the
flue hole.
NOTICE
Summary of Contents for Energysaver EX17C
Page 31: ...Rinnai Corporation EX17C EX22C Manual 31 Cut Away Diagram ...
Page 35: ...Rinnai Corporation EX17C EX22C Manual 35 Parts List ...
Page 36: ...36 Rinnai Corporation EX17C EX22C Manual Parts List ...
Page 37: ...Rinnai Corporation EX17C EX22C Manual 37 Parts List ...
Page 38: ...38 Rinnai Corporation EX17C EX22C Manual Parts List ...
Page 39: ...Rinnai Corporation EX17C EX22C Manual 39 Parts List ...
Page 81: ...Rinnai Corporation EX17C EX22C Manual 81 Notes ...
Page 82: ...82 Rinnai Corporation EX17C EX22C Manual Notes ...
Page 83: ...Rinnai Corporation EX17C EX22C Manual 83 Notes ...