INSTALLATION - SOLAR COLLECTORS
Rinnai 20
DD FP Solar Pre Heat System OIM
FLOW AND RETURN LINE LAYOUT
To ensure that the system is operating at optimum efficiency, it is important to ensure that the flow through all the
collector arrays is balanced. This can be achieved by using the ‘first in last out’ approach to ensure equal length
flow and return lines for all collector arrays as shown below.
Alternatively balancing valves may be used on each collector array. This may simplify the pipework layout and
cost.
COLLECTOR FITTING DETAILS
Enduro SP200B
Cap
Hot Sensor Lead
Hot Sensor
Assembly
Hot Sensor Assembly and Lead
only on one set of collectors
Remainder have connection to
hot return pipework.
Cap
Union
Barrel Union
Barrel Union