Rinnai Demand Rapid DD1200E315L Owner And Installer Manual Download Page 7

Demand Rapid owner & installer guide 12949-B 02-19 |  

 

Troubleshooting: Rinnai INFINITY error codes

troubleshooting with controllers or status monitor

Your Rinnai INFINITY has a self diagnostic capability. If a fault occurs, an error code will flash 

on the status monitor (HD200 external and EF models) or on the digital controller (if fitted). This 

assists with diagnosing the fault and may enable you to overcome a problem without a service call. 

Please quote the code displayed when contacting Rinnai.
In some cases you may be able to clear the error code by turning the lower water valve off, wait 20 

seconds, then on again.

Error 

code

Fault

Possible solution

-

Noticeable reduction in water flow

Inlet water filter needs to be cleaned—service call.

03

Power interruption, water will not flow 

when power is back on

Turn off all hot water taps and press On/Off (on the controller 

twice)

10

Combustion fan current is too high. Unit 

operates then stops.

Owner: Service call

Installer: Check blockage of air intake/flue outlet, and combustion 

fan.

11

No ignition. Unit stops without flame 

igniting.

Owner: Check gas is turned on at the water heater, gas meter, or 

cylinder.

Installer: Check; gas supply, sparker unit, and gas valves.

12

Flame failure, earth leakage

Owner: Check gas is turned on at the water heater, gas meter, or 

cylinder. Check there are no obstructions to the flue outlet.

Installer: Check; gas supply, flame rod, earth wire lead, and water 

control.

14

Thermal fuse and/or OH switch 

activated. Unit operates then stops.

Owner: Service call

Installer: Check thermal fuse and OH switch. If either are faulty 

check the heater for damage, confirm gas type, pressure settings, 

and test point pressures.

16

Over temperature warning. Unit 

operates then stops.

Owner: Service call

Installer: Confirm gas type, pressure settings, and test point 

pressures. Check; gas valves, water flow sensor and servo, and 

HEX outlet temperature thermistor.

25

Condensate trap error

Check condensate drain for blockage

32

Outlet water temperature faulty

Owner: Service call

Installer: Check hot water outlet thermistor

33

Heat exchanger outlet sensor faulty

Owner: Service call

Installer: Check HEX thermistor

34

Air temperature sensor faulty (internal 

models only)

Service call. Will require; checking sensor wiring for damage, 

measuring sensor resistance, checking combustion fan, checking 

internal flue leakage, checking flue system integrity, and possibly 

replacing the sensor

52

Modulating solenoid valve fault. Unit 

stops without flame ignition.

Owner: Service call

Installer: Check modulating solenoid valve

61

Combustion fan failure

Owner: Service call. Installer: Check combustion fan.

65

Water flow control error. Water flow is 

not controlled. Water temperature too 

low.

Owner: Service call. 

Installer: Check water flow servo.

71

Solenoid valve circuit error. Unit does 

not operate.

Owner: Service call. 

Installer: Check gas valves

72

Flame rod circuit error. Unit does not 

operate.

Owner: Service call. 

Installer: Check flame rod

LC

Scale buildup in heat exchanger—when 

checking maintenance code history, 00 

is substituted for LC

Service call

Summary of Contents for Demand Rapid DD1200E315L

Page 1: ...y storage system Owner and installer guide Models DD1200E315N L DD1200i315N L DD1212E315N L DD1212i315N L DD1250E315N L Installer Please leave this guide with the owner as it contains important safety...

Page 2: ...d by an authorised person being in New Zealand a licensed gasfitter Warning Improper installation adjustment alteration service and maintenance can cause property damage personal injury or loss of lif...

Page 3: ...ummary 9 DD1200E315 specification 10 DD1200i315 specification 11 DD1212E315 specification 12 DD1212i315 specification 13 DD1250E315 specification 14 Location 15 General installation information 16 Del...

Page 4: ...o not block or seal the valve s or drain pipe s The system must not be operated unless these devices are fitted and are in good working order Rinnai INFINITY safety devices flame failure boil dry prot...

Page 5: ...uired whenever the appliance is connected to the power supply If power has failed and there is risk of damage from frost turn off the gas supply to the unit and open a tap slightly to allow flow throu...

Page 6: ...ths may result in the water heater exploding Continuous leaking of water from the valve s may indicate a problem It is important that you raise and lower the easing gear gently During operation if the...

Page 7: ...4 Thermal fuse and or OH switch activated Unit operates then stops Owner Service call Installer Check thermal fuse and OH switch If either are faulty check the heater for damage confirm gas type press...

Page 8: ...operation errors are not covered by the Rinnai warranty Troubleshooting general system troubleshooting What s happening Possible cause Explanation and or possible solution Delivery temperature not ho...

Page 9: ...residential applications where a large quantity of hot water is required quickly but there is recovery time available before next use For example filling a machine or spa bath Hard or aggressive water...

Page 10: ...MJ h Output 45 9 kW Weights Empty 82 kg Full 402 kg Water pressure Min 150 kPa Max 850 kPa Hot water delivery Raised 25 C 1500 L h Raised 35 C 1250 L h Raised 45 C 950 L h Raised 50 C 875 L h Raised 5...

Page 11: ...Output 44 5 kW Weights Empty 82 kg Full 402 kg Water pressure Min 150 kPa Max 850 kPa Hot water delivery Raised 25 C 1500 L h Raised 35 C 1250 L h Raised 45 C 950 L h Raised 50 C 875 L h Raised 55 C...

Page 12: ...7 kW Weights Empty 90 kg Full 410 kg Water pressure Min 150 kPa Max 850 kPa Hot water delivery Raised 25 C 1700 L h Raised 35 C 1400 L h Raised 45 C 1200 L h Raised 50 C 1100 L h Raised 55 C 1000 L h...

Page 13: ...55 7 kW Weights Empty 90 kg Full 410 kg Water pressure Min 150 kPa Max 850 kPa Hot water delivery Raised 25 C 1700 L h Raised 35 C 1400 L h Raised 45 C 1200 L h Raised 50 C 1100 L h Raised 55 C 1000 L...

Page 14: ...tput 57 8 kW Weights Empty 90 kg Full 410 kg Water pressure Min 150 kPa Max 850 kPa Hot water delivery Raised 25 C 1700 L h Raised 35 C 1400 L h Raised 45 C 1200 L h Raised 50 C 1100 L h Raised 55 C 1...

Page 15: ...omponents Where the system is not accessible the Rinnai warranty will not cover any additional costs caused by access difficulty The system must be accessible without the use of a ladder or scaffold C...

Page 16: ...rage water heater to reduce the temperature 2 Re plumb the INFINITY gas water heater to the hot water return connection as shown This will reduce the hot water temperature being delivered to approxima...

Page 17: ...other restrictions should not be installed with the relief vent line TPR valve drain line should not be joined to other drain lines Gas connection Check gas type of the Rinnai INFINITY matches the ga...

Page 18: ...reprogrammed contact Rinnai for assistance If hotter water is required the cylinder and the Rinnai INFINITY dip switches will need to be adjusted 8 Plug 3 core flex into suitably earthed general powe...

Page 19: ...installer guide 12949 B 02 19 19 Commissioning Fill the cylinder as detailed on the previous page and commission the Rinnai INFINITY in accordance with the commissioning sheet attached to the front c...

Page 20: ...press warranty period recorded in the table above This warranty does not limit any consumer rights or guarantees that may apply under the Consumer Guarantees Act 1993 If the product is being acquired...

Page 21: ...authorised service centre travel costs shall be the owner s responsibility Warranty exclusions The following exclusions may cause the warranty to become void and will result in a service charge and c...

Page 22: ...tinuous fall of at least 2 from water heater to discharge point Lengths and bends in accordance with the table below Lengths and changes of direction Max length m 9 8 7 6 Max changes of direction grea...

Page 23: ...ith any adjacent soil or waste stack The discharge point of the common stack is such that any discharge is readily visible and will not cause any nuisance The common stack is vented by extending the p...

Page 24: ...Rinnai co nz 0800 746 624 http www youtube com rinnainz http www facebook com rinnainz 12949 B...

Reviews: