Rinnai
9
Split AC IM
INDOOR UNIT
Wall Mounting Plate
1� The wall or structure on which the units are to be mounted must be capable of supporting the weight of the
appliance and the associated pipe-work�
2�
Fix the mounting plate on to the wall using, ensuring that it is both level and firmly mounted with the appropriate
fixings.
CAUTION
DO NOT install the unit in a place where electrical wiring or conduits are located
�
C
B
Ø70
A
E
D
Wall Mounting Plate Positioning Dimensions (mm)
HINCJ25B
HINCJ35B
HINCJ50B
HINCJ70B
A
B
C
D
E
A
B
C
D
E
A
B
C
D
E
A
B
C
D
E
294 881 228 84
43 316 940 218 54
41 316 997 217 43
38 330 1132 236 56
39
Wall Penetration
Drill a Ø70mm wall penetration through the wall with a 2° to 4° fall to the outside wall�
Drain Pipe
1� Connect the drain pipe to the drain hose outlet of the indoor unit,
2� Bind the joint with PVC insulation tape (not supplied)�
INSIDE
OUTSIDE
2° to 4° fall
INSTALLATION