Rinnai Circ-Logic Installation And Operation Manual Download Page 11

 

Rinnai Circ

-

Logic with Grundfos GTK03 Kit

 

 

 

 

 

 

11

 

Rinnai

 

Temperature 

Setting (°F)

 

Typical Pump ON 

 

Intervals* (minutes)

 

Economy Mode

 

Comfort Mode

 

140

 

31

 

15

 

135

 

31

 

15

 

130

 

31

 

15

 

125

 

31

 

15

 

120

 

31

 

15

 

115

 

35

 

18

 

110

 

42

 

21

 

108

 

45

 

22

 

106

 

49

 

24

 

104

 

54

 

27

 

102

 

60

 

30

 

100

 

68

 

34

 

98

 

79

 

39

 

*

 

The pump will cycle on at these calculated 
intervals which are based on the temperature 

setting, insulation, and estimated heat loss in the 

system. The values for your installation may vary.

 

Before operating the pump, the Rinnai Tankless  
Water Heater should be turned on and the DIP 
switches/parameters set correctly for recirculation 
and Comfort or Economy Mode. 

 

Pump recirculation begins when the water heater 
is turned on. The Rinnai inlet and outlet 
thermistors measure the water temperature. If the 
inlet thermistor detects abnormal temperature, 
then diagnostic code 51 is generated and the 
pump will turn off. 

 

When the return water temperature reaches 
approximately 15°F (8.3°C) below the 
temperature setting, the water heater and pump 
will turn off.

 

The cycle will start at the approximate time 
interval in the table based on the recirculation 
mode setting. The cycle stops based on the 
temperature thermistor readings.

 

When the pump is first started, the shaft may rotate slowly until water has fully penetrated the bearings. 

If the pump does not run, the shaft can be rotated manually. To accomplish this, switch off the electrical 

supply and close the isolation valves on each side of the pump. Remove the large screw in the middle of 

the nameplate. Insert a small, flat blade screwdriver into the end of the shaft, and gently turn until the 

shaft moves freely (Figure 4). Replace and tighten the plug. Open the isolation valves and wait 2 to 3 

minutes for the system pressure to equalize before starting the pump (Figure 4).

 

Figure 4

 

  NOTE

 

The isolation valves are to be field 

supplied. The image to the right is for 

illustration purposes only. 

 

Summary of Contents for Circ-Logic

Page 1: ...For SENSEI and non SENSEI Tankless Water Heaters...

Page 2: ...ion 6 2 1 Wiring the Pump to the Water Heater 6 2 2 Parameter Settings 7 3 Non SENSEI Installation 8 3 1 Wiring the Pump to the Water Heater 8 4 Operating the Pump 11 4 1 How It Works 11 4 2 Troublesh...

Page 3: ...Grundfos allows the user to enjoy Circ Logic with VC KB and SENSEI series tankless water heaters on a dedicated return line with the use of an external pump For all models Circ Logic operates in eith...

Page 4: ...mp In line 4 amp glass fuse included Union Set Rinnai Circ Logic Manual A licensed professional must install the GTK03U kit The installer should have the following skills Connecting gas lines water li...

Page 5: ...tion of the pump will have the terminal box located to one side of the pump or the other with the conduit entry down Figure 1A The arrows on the side or bottom of the pump housing indicate direction o...

Page 6: ...r supply to the building WARNING 1 Turn off the electrical power supply by unplugging the power cord or by turning off the electricity at the circuit breaker Remove the front panel of the water heater...

Page 7: ...g Setting Description Selection a 04 Recirculation Settings No Recirculation Recirculation Dedicated 05 Recirculation Mode1 Economy Comfort 1 Setting 05 is available only if setting 04 is selected c A...

Page 8: ...power Turn off the gas at the manual gas valve usually located immediately below the water heater Turn off the incoming water supply This can be done by turning off the water supply to the building W...

Page 9: ...or the recirculation pump is bundled with the wire harness from the PC Board the pump wiring is labeled to show where to connect to the tankless water heater The connector from the tankless water heat...

Page 10: ...before servicing WARNING RISK OF ELECTRIC SHOCK All Components Within Dashed Line Inside of Water Heater Connect Ground to Tankless Housing 7 Adjust the dip switch in the water heater by moving the 4...

Page 11: ...and the pump will turn off When the return water temperature reaches approximately 15 F 8 3 C below the temperature setting the water heater and pump will turn off The cycle will start at the approxim...

Page 12: ...Rinnai Circ Logic with Grundfos GTK03 Kit 12 Figure 5 Hot Water Outlets Check Valve Cold Water Supply Gas Supply Condensate Drain Line 3 4 in Return Line Recommended GTK03U Pump Expansion Tank...

Page 13: ...tem to be installed The drawing does not imply compliance with local building code requirements It is the responsibility of the engineer or contractor to ensure that the installation is in accordance...

Page 14: ...that the installation is in accordance with all local building codes Confer with local building officials before installation Cold Water Supply Gas Supply Hot Water Outlets Circulating Unit Non Circul...

Page 15: ......

Reviews: