Temperature Control

Water controllers allow precise temperature control by the user. When used correctly, the hot water unit will deliver 

the selected temperature, even when the water flow is varied, or more than one tap is in use. 

Only one MC model water controller can be designated as a ‘Master’ water controller and this is normally used 

in the kitchen. All the remaining water controllers are designated as ‘Sub’ water controllers and are for use in 

bathrooms, toilets and laundries. The maximum temperature limit for all ‘Sub’ water controllers is restricted to 50°C 

to minimise the risk of burns in these areas. 
Each water controller can be individually programmed, however the water heater can only deliver one set 

temperature at any time. The available temperatures (°C) are as follows:

Water Controller 

Temperatures (°C)**

Master (MC)

37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 50, 55*, 60*, 65*

Sub (MC or BC)

37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 50

For hygiene in sanitary areas such as bathrooms, the suggested temperature should be 37°C ~ 43°C.

The  above  is  a  suggestion  only,  as  you  may  find  higher  or  lower  temperatures  more  comfortable,  however 

maintaining lower temperatures also helps to save energy.
To obtain water temperatures lower than 37°C, simply open the cold water tap and add cold water until the desired 

lower temperature is reached.

NOTE

The temperature of outgoing hot water is constantly monitored by a built-in sensor� If the 

temperature of the outgoing hot water rises to more than 3°C above the selected temperature 

shown on the digital monitor or the pre-set limit when water controllers are not fitted, the burner 

will automatically go out� The ‘in use’ indicator   will also go out� The burner will ignite again 

once the outgoing hot water temperature falls to that shown on the digital monitor (or the pre-set 

limit of the appliance)

*

 Temperature may not be available on all installations� Some Rinnai Continuous Flow water 

heaters can be programmed to deliver higher temperatures from the master water controller, or 

may be programmed to restrict the maximum available delivery temperature� Contact Rinnai for 

more details�

**  Temperature  limiting  devices  (where  fitted)  may  further  control  what  maximum  delivery 

temperature is available to outlets�

Universal and Wireless and water controllers allow temperature selection only. Deluxe water controllers allow 

temperature selection, have a clock function and the Deluxe Bathroom water controller has a shower saver / bath 

fill function is also available, contact Rinnai for further information regarding Wireless and Deluxe water controllers 

or visit www.rinnai.com.au.

WATER CONTROLLER COMBINATIONS & CONFIGURATIONS

Wired Only Configurations

• 

A maximum of 4 water controllers can be fitted. Any combination of deluxe and universal controllers can be 

used with the following limitations:

• 

Only 

ONE

 master controller can be installed. This can be a MC-100V, or a MC-601Q (when programmed as 

a master controller). Note that when a MC-100V is fitted it will always functions as a master controller, this 

is the default setting and can not be changed.

• 

Up to 

TWO

 BC-100V water controllers can be installed.

• 

The 

FOURTH

 water controller in any installation MUST BE a MC-601Q.

Combined Wireless & Wired Configurations

• 

A maximum of 4 water controllers can be fitted. Any combination of deluxe, universal and wireless controllers 

can be used with the following limitations:

• 

Only 

ONE

 master controller can be installed. This can be a MC-100V, a MC-601Q (when programmed as 

a master controller) or a MC-503RC-S water controller. Note that when a MC-100V is fitted it will always 

functions as a master controller, this is the default setting and can not be changed. 

• 

Up to 

TWO

 BC-100V water controllers can be installed.

• 

The 

FOURTH

 water controller in any installation MUST BE a MC-503RC-S or a MC-601Q.

WATER TEMPERATURE CONTROL

Summary of Contents for BC-100V

Page 1: ...water heater and other remote controller models shown Refer to page 6 of this manual to confirm the maximum number and combination of control lers that can be fitted to your Rinnai water heater model This appliance must be installed in accordance with Manufacturer s Installation Instructions Current AS NZS 3000 AS NZS 3500 AS NZS 5601 Local Regulations and Municipal Building Codes including local ...

Page 2: ...Rinnai 2 HW_CF_DELUXE OIM This page is intentionally blank ...

Page 3: ... The Clock 8 Water Controller Combinations Configurations 8 Deluxe Bathroom Water Controller BC 100V 9 Turning On 9 Adjusting Temperature 9 Transferring Priority 10 Setting The Sound Options 10 Setting The Clock 10 Setting Shower Saver Bath Fill 11 Using Shower Saver Bath Fill 12 Water Controller Combinations Configurations 12 Smartstart Pre Heat System 13 Preheat Function 13 Preheat Operation 13 ...

Page 4: ...s water and electricity must conform to local regulations including local OH S requirements The installation must also comply with the instructions supplied by Rinnai Please keep this instruction booklet in a safe place for future reference All dimensions referred to in these instructions are in millimetres unless otherwise specified WARNING WARNING ABOUT HOT WATER Hot water can cause scalding Tho...

Page 5: ...limit of the appliance Temperature may not be available on all installations Some Rinnai Continuous Flow water heaters can be programmed to deliver higher temperatures from the master water controller or may be programmed to restrict the maximum available delivery temperature Contact Rinnai for more details Temperature limiting devices where fitted may further control what maximum delivery tempera...

Page 6: ...e priority transferred to the water controller you wish to use Illuminated On Off and Transfer buttons confirm that the desired controller is in control of the water delivery temperature If the On Off button is not illuminated press the Transfer button once the On Off and Transfer buttons will illuminate indicating that hot water temperature control has been transferred and that the hot water unit...

Page 7: ... flash Use the or buttons to select the desired time holding these buttons down continuously cycles the digits When you get close to the time you wish to set press the button intermittently to avoid going further than the desired time To return to normal operation press the Mode button once NOTE If no buttons are pressed for a period of approximately 60 seconds the controller will return to normal...

Page 8: ...mmand of the hot water delivery temperature This button is illuminated when this controller has priority TRANSFER BUTTON SPEAKER Used to start and stop the Smartstart preheat unit when fitted See Smartstart Operation on page 12 This button is illuminated when the Smartstart preheater when fitted is activated PREHEAT BUTTON Indicates the selected hot water temperature WATER TEMPERATURE INDICATOR In...

Page 9: ...r buttons to return to normal operation NOTE If no buttons are pressed for a period of approximately 10 seconds the controller will return to normal operation Setting The Clock The clock is a 12 hour AM PM style display To set the time press the Clock button once this places the controller into clock setting mode in the digital monitor the clock digits will flash Use the Temperature or buttons to ...

Page 10: ...efault Shower Saver Bath Fill temperature until it is changed or if the mains power is turned off for an extended period To select the volume of water to be used in the shower bath use the Water Volume or buttons The selected volume is displayed in large digits to the right and will remain as the default Water Volume until it is changed or if the mains power is turned off for an extended period Th...

Page 11: ...from the shower bath hot water tap ceases 2 The Shower Saver Bath Fill button will flash 3 The Deluxe Kitchen water controller Bath indicator will flash 4 A tone will sound 5 The voice prompt will say Bath fill is complete Turn off the bath hot water tap and push the Bath Fill button Follow the voice prompts instructions NOTE The water heater will not allow hot water to flow from any fixture until...

Page 12: ...e Control buttons 6 until the required temperature is displayed in the digital monitor 3 2 Press the Preheat button 1 once The Preheat indicator 2 and the In Use indicator 7 will illuminate signifying that the preheat system has been activated 3 Wait approximately two minutes before opening an outlet This will allow the water in the pipework to be warmed NOTE The waiting time may be longer or shor...

Page 13: ...to 50 C the maximum temperature that the water heater will deliver is 50 C In this case 55 C will be displayed on the wireless Master Controller until a tap is opened after which the display will revert to 50 C IMPORTANT The water heater maximum temperature cannot be adjusted by the user These adjustments can ONLY be carried out by a qualified and licensed trades person The remaining water control...

Page 14: ... resistant device however excessive exposure to water may result in damage to the water controller Durability is improved when positioned outside the shower recess AVOID direct exposure to water or steam as these conditions may cause a malfunction Water controllers must be installed in shaded and clean locations They should be fitted out of reach of children suggested height from floor to be at le...

Page 15: ...heater unless the electric power to the water heater is switched off otherwise damage to electrical components may occur If your water heater is not fitted with an Ezi connect cable connector installation must be completed by a qualified and licensed trades person 1 Isolate the electric power supply by switching the power point off and removing the power plug of the water heater from the electric ...

Page 16: ...LCD difficult to see at direct eye level For best results when Installing the MC 100V mount the remote controller lower than your eye level to avoid these light reflections DELUXE BATHROOM WATER CONTROLLER BC 100V 1 Determine the most suitable position refer Location on page 14 2 Using the wall mounting bracket as a template mark and drill 3 holes mounting and cable access refer to Diagram 1 Dimen...

Page 17: ...tres 181 F Cable Access Hole Size Position Ø20 ii Ø20 Centre i The MC 100V uses a metal mounting bracket that has 3 upper and lower mounting points both on and either side of the vertical centre line ii The MC 100V cable access is horizontally offset to the right of the centreline inside the metal mounting bracket refer to dimensional diagram below for correct cable access hole positioning BC 100V...

Page 18: ...Rinnai 18 HW_CF_DELUXE OIM NOTES ...

Page 19: ...Rinnai 19 HW_CF_DELUXE OIM NOTES ...

Page 20: ...th our policy of continuous improvement we reserve the right to change or discontinue at any time specifications or designs without notice Australia Pty Ltd ABN 74 005 138 769 100 Atlantic Drive Keysborough Victoria 3173 P O Box 460 Braeside Victoria 3195 AU45204 Product Sales Service National Help Line Tel 1300 555 545 Fax 1300 555 655 Monday to Friday 8 00am to 5 30pm EST For further information...

Reviews: